Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.502 kW
06/30/2025 17:00 (1860 days) Production Consumption NET Usage
Now 2.457 kW 1.955 kW -0.502 kW
Today 25.072 kWh (1.473 kW) 17.863 kWh (1.049 kW) -7.209 kWh (-0.423 kW)
  - This Week 55.030 kWh (32.204 kWh/day) 54.882 kWh (32.117 kWh/day) -0.148 kWh (-0.087 kWh/day)
  - This Month 626.319 kWh (21.082 kWh/day) 760.516 kWh (25.599 kWh/day) 134.197 kWh (4.517 kWh/day)
  - This Year 3.027 MWh (16.753 kWh/day) 3.114 MWh (17.235 kWh/day) 0.087 MWh (0.481 kWh/day)
Yesterday 29.958 kWh (1.249 kW) 37.019 kWh (1.543 kW) 7.061 kWh (0.294 kW)
Last 7 Days 164.939 kWh (23.565 kWh/day) 274.127 kWh (39.165 kWh/day) 109.188 kWh (15.600 kWh/day)
Last 30 Days 617.926 kWh (20.598 kWh/day) 775.650 kWh (25.855 kWh/day) 157.724 kWh (5.257 kWh/day)
Last One Year 6.346 MWh (17.387 kWh/day) 6.392 MWh (17.513 kWh/day) 0.046 MWh (0.126 kWh/day)
Lifetime Since PTO 32.478 MWh (17.455 kW/day) 35.066 MWh (18.846 kW/day) 2.588 MWh (1.391 kW/day)
Lifetime Since Install 32.512 MWh 35.646 MWh 3.134 MWh
Voltage/Current 247.6 V / 9.9 A 247.4 V / 7.9 A 247.5 V / -2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/17/2022 22:51 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.686 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.196 0.542 1.109 8.869 0.000 kW
0.532 kWh
0.000 kW
3.193 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.521 1.015 8.393
03 - 202224****** IQ7+M [5] VCOP 0.000 0.199 0.555 1.067 8.746
04 - 202232****** IQ7+ [5] VCOP 0.000 0.197 0.519 1.051 8.486
05 - 202244****** IQ7+M [5] VCOP 0.000 0.194 0.537 1.047 8.604
06 - 202245****** IQ7+M [5] VCOP 0.000 0.189 0.519 1.067 8.424
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.227 0.542 1.224 9.173 0.000 kW
0.567 kWh
0.000 kW
2.835 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.226 0.577 1.256 9.683
09 - 202217****** IQ7+ [5] VCOP 0.000 0.228 0.569 1.239 9.801
10 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.571 1.244 9.832
11 - 202224****** IQ7+M [5] VCOP 0.000 0.226 0.576 1.251 9.839
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.146 0.414 0.776 5.737 0.000 kW
0.415 kWh
0.000 kW
1.659 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.143 0.412 0.788 5.953
14 - 202216****** IQ7+ [5] VCOP 0.000 0.147 0.428 0.788 5.991
15 - 202245****** IQ7+M [5] VCOP 0.000 0.146 0.404 0.765 5.806
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.46 V Current/Power -12.95 A (-0.679 kW)
Remain Capacity/Energy 261.6 Ah (13.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 43.6 % State Of Health 100.0 %
Run Time 20h 12m to empty Report Date 2022-10-17 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.47 V Cell (MIN/MAX) 3.273 V / 3.285 V (0.012 V)
Current/Power -3.87 A (-202 W) Runtime 22h 33m to empty
Remain Capacity/Energy 87.2 Ah (4.5 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 43.6 % State Of Health 100.0 %
Temperature 25.0 °C Cycle 80
MOSFET CFET = ON, DFET = ON Reported 2022-10-17 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.274 V 3.273 V 3.275 V 3.278 V 3.276 V 3.276 V 3.280 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.281 V 3.280 V 3.284 V 3.280 V 3.285 V 3.284 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.