Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.389 kW
01/11/2025 01:57 (1690 days) Production Consumption NET Usage
Now 0.000 kW 0.389 kW 0.389 kW
Today 0.000 kWh (0.000 kW) 1.276 kWh (0.642 kW) 1.276 kWh (0.642 kW)
  - This Week 67.866 kWh (11.157 kWh/day) 134.818 kWh (22.164 kWh/day) 66.952 kWh (11.007 kWh/day)
  - This Month 100.985 kWh (10.016 kWh/day) 240.591 kWh (23.863 kWh/day) 139.606 kWh (13.847 kWh/day)
  - This Year 0.101 MWh (10.016 kWh/day) 0.241 MWh (23.863 kWh/day) 0.140 MWh (13.847 kWh/day)
Yesterday 13.185 kWh (0.550 kW) 21.592 kWh (0.900 kW) 8.407 kWh (0.350 kW)
Last 7 Days 79.889 kWh (11.413 kWh/day) 150.714 kWh (21.531 kWh/day) 70.825 kWh (10.118 kWh/day)
Last 30 Days 253.992 kWh (8.467 kWh/day) 665.111 kWh (22.171 kWh/day) 411.119 kWh (13.704 kWh/day)
Last One Year 6.733 MWh (18.447 kWh/day) 6.299 MWh (17.258 kWh/day) -0.434 MWh (-1.189 kWh/day)
Lifetime Since PTO 29.552 MWh (17.485 kW/day) 32.193 MWh (19.048 kW/day) 2.641 MWh (1.563 kW/day)
Lifetime Since Install 29.586 MWh 32.773 MWh 3.188 MWh
Voltage/Current 250.8 V / 0.0 A 250.8 V / 1.6 A 250.8 V / 1.6 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 05/22/2022 21:59 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.168 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.228 0.646 2.120 11.467 0.000 kW
0.608 kWh
0.000 kW
3.649 kWh
02 - 202244177619 IQ7+M V--- 0.000 0.224 0.600 2.040 10.858
03 - 202224101754 IQ7+M ---- 0.000 0.229 0.631 2.123 11.276
04 - 202232127100 IQ7+ ---- 0.000 0.229 0.610 2.081 11.050
05 - 202244171601 IQ7+M ---- 0.000 0.214 0.555 2.008 10.600
06 - 202245013024 IQ7+M ---- 0.000 0.223 0.606 2.039 10.901
front 07 - 202206091803 IQ7+ ---- 0.000 0.197 0.576 2.032 10.780 0.000 kW
0.567 kWh
0.000 kW
2.836 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.197 0.542 1.968 10.468
09 - 202217001404 IQ7+ ---- 0.000 0.197 0.558 1.972 10.512
10 - 202244165234 IQ7+M ---- 0.000 0.196 0.576 2.029 10.761
11 - 202224104308 IQ7+M ---- 0.000 0.194 0.585 2.058 10.956
back 12 - 202211186551 IQ7+ ---- 0.000 0.259 0.679 1.806 10.810 0.000 kW
0.671 kWh
0.000 kW
2.683 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.259 0.648 1.724 10.385
14 - 202216155993 IQ7+ ---- 0.000 0.262 0.682 1.824 10.880
15 - 202245015670 IQ7+M ---- 0.000 0.260 0.674 1.798 10.731
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.20 V Current/Power -1.32 A (-70 W)
Remain Capacity/Energy 503.4 Ah (25.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.9 % State Of Health 100.0 %
Run Time 15d 21h 21m to empty Report Date 2022-05-22 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.17 V Cell (MIN/MAX) 3.318 V / 3.327 V (0.009 V)
Current/Power -0.44 A (-23 W) Runtime 16d 0h 51m to empty
Remain Capacity/Energy 167.8 Ah (8.6 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 83.9 % State Of Health 100.0 %
Temperature 22.0 °C Cycle 65
MOSFET CFET = ON, DFET = ON Reported 2022-05-22 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.319 V 3.319 V 3.320 V 3.321 V 3.321 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.325 V 3.325 V 3.326 V 3.327 V 3.327 V 3.327 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.324 V / 3.325 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 21.2 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-22 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.324 V 3.324 V 3.325 V 3.325 V 3.324 V
pack voltage and current cell voltages
pack temperature
Voltage 53.23 V Cell (MIN/MAX) 3.326 V / 3.327 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 22.5 °C Cycle 17
MOSFET CFET = ON, DFET = ON Reported 2022-05-22 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.327 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage 53.18 V Cell (MIN/MAX) 3.323 V / 3.324 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 22.9 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-22 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.324 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.2 Ah (5.1 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.7 %
Temperature 21.6 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-22 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.324 V 3.325 V 3.325 V 3.324 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.325 V 3.323 V 3.324 V 3.324 V 3.325 V 3.324 V 3.325 V
pack voltage and current cell voltages
pack temperature