Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.186 kW
05/22/2026 20:29 (2186 days) Production Consumption NET Usage
Now 0.000 kW 0.186 kW 0.186 kW
Today 29.595 kWh (1.443 kW) 4.209 kWh (0.205 kW) -25.386 kWh (-1.238 kW)
  - This Week 155.372 kWh (26.538 kWh/day) 148.373 kWh (25.343 kWh/day) -6.999 kWh (-1.195 kWh/day)
  - This Month 557.188 kWh (25.496 kWh/day) 348.095 kWh (15.928 kWh/day) -209.093 kWh (-9.568 kWh/day)
  - This Year 2.510 MWh (17.696 kWh/day) 2.408 MWh (16.974 kWh/day) -0.102 MWh (-0.722 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.534 kWh (22.362 kWh/day) -31.756 kWh (-4.537 kWh/day)
Last 30 Days (04/22/2026) 721.023 kWh (24.034 kWh/day) 419.997 kWh (14.000 kWh/day) -301.026 kWh (-10.034 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.791 MWh (21.344 kWh/day) 1.399 MWh (3.833 kWh/day)
Lifetime Since PTO 38.076 MWh (17.411 kW/day) 41.919 MWh (19.168 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.499 MWh 4.389 MWh
Voltage/Current 249.4 V / 0.0 A 249.5 V / 0.7 A 249.5 V / 0.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/05/2023 23:54 (20.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.950 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.247 1.604 1.591 7.948 0.000 kW
1.563 kWh
0.000 kW
9.376 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.236 1.532 1.519 7.569
03 - 202224****** IQ7+M [0] ---- 0.000 0.244 1.584 1.572 7.844
04 - 202232****** IQ7+ [0] ---- 0.000 0.248 1.599 1.589 7.892
05 - 202244****** IQ7+M [0] ---- 0.000 0.238 1.516 1.502 7.441
06 - 202245****** IQ7+M [0] ---- 0.000 0.242 1.541 1.525 7.603
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.278 1.608 1.589 7.750 0.000 kW
1.721 kWh
0.000 kW
8.606 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.279 1.731 1.716 8.274
09 - 202217****** IQ7+ [0] ---- 0.000 0.278 1.748 1.725 8.315
10 - 202244****** IQ7+M [0] ---- 0.000 0.275 1.745 1.722 8.294
11 - 202224****** IQ7+M [0] ---- 0.000 0.282 1.775 1.754 8.438
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.165 1.014 1.004 5.425 0.000 kW
1.077 kWh
0.000 kW
4.310 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.170 1.070 1.053 5.684
14 - 202216****** IQ7+ [0] ---- 0.000 0.174 1.114 1.098 5.924
15 - 202245****** IQ7+M [0] ---- 0.000 0.174 1.112 1.096 5.921
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.329 kWh
0.000 kW
4.659 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.230 4.659 5.478 20.160
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.