Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.008 kW
01/11/2025 01:15 (1690 days) Production Consumption NET Usage
Now 0.000 kW 1.008 kW 1.008 kW
Today 0.000 kWh (0.000 kW) 0.865 kWh (0.674 kW) 0.865 kWh (0.674 kW)
  - This Week 67.866 kWh (11.211 kWh/day) 134.407 kWh (22.204 kWh/day) 66.541 kWh (10.992 kWh/day)
  - This Month 100.985 kWh (10.045 kWh/day) 240.180 kWh (23.892 kWh/day) 139.195 kWh (13.846 kWh/day)
  - This Year 0.101 MWh (10.045 kWh/day) 0.240 MWh (23.892 kWh/day) 0.139 MWh (13.846 kWh/day)
Yesterday 13.185 kWh (0.550 kW) 21.592 kWh (0.900 kW) 8.407 kWh (0.350 kW)
Last 7 Days 79.889 kWh (11.413 kWh/day) 150.714 kWh (21.531 kWh/day) 70.825 kWh (10.118 kWh/day)
Last 30 Days 253.992 kWh (8.467 kWh/day) 665.111 kWh (22.171 kWh/day) 411.119 kWh (13.704 kWh/day)
Last One Year 6.733 MWh (18.447 kWh/day) 6.299 MWh (17.258 kWh/day) -0.434 MWh (-1.189 kWh/day)
Lifetime Since PTO 29.552 MWh (17.485 kW/day) 32.193 MWh (19.048 kW/day) 2.641 MWh (1.563 kW/day)
Lifetime Since Install 29.586 MWh 32.773 MWh 3.187 MWh
Voltage/Current 250.3 V / 0.0 A 250.2 V / 4.0 A 250.3 V / 4.0 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 05/29/2022 21:59 (14.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.210 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.296 2.141 1.271 10.492 0.000 kW
2.022 kWh
0.000 kW
12.129 kWh
02 - 202244177619 IQ7+M V--- 0.000 0.296 2.016 1.242 9.933
03 - 202224101754 IQ7+M ---- 0.000 0.296 2.050 1.287 10.354
04 - 202232127100 IQ7+ ---- 0.000 0.297 2.001 1.255 10.226
05 - 202244171601 IQ7+M ---- 0.000 0.295 1.863 1.263 9.751
06 - 202245013024 IQ7+M ---- 0.000 0.295 2.058 1.244 9.981
front 07 - 202206091803 IQ7+ ---- 0.000 0.297 1.943 1.219 9.608 0.000 kW
1.917 kWh
0.000 kW
9.586 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.297 1.863 1.133 9.443
09 - 202217001404 IQ7+ ---- 0.000 0.296 1.882 1.182 9.461
10 - 202244165234 IQ7+M ---- 0.000 0.296 1.923 1.236 9.626
11 - 202224104308 IQ7+M ---- 0.000 0.296 1.975 1.254 9.735
back 12 - 202211186551 IQ7+ ---- 0.000 0.291 2.157 1.162 10.338 0.000 kW
2.124 kWh
0.000 kW
8.495 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.291 2.048 1.132 10.189
14 - 202216155993 IQ7+ ---- 0.000 0.293 2.161 1.178 10.479
15 - 202245015670 IQ7+M ---- 0.000 0.293 2.129 1.165 10.377
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.23 V Current/Power -1.29 A (-68 W)
Remain Capacity/Energy 489.0 Ah (25.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 81.5 % State Of Health 100.0 %
Run Time 15d 19h 4m to empty Report Date 2022-05-29 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.20 V Cell (MIN/MAX) 3.319 V / 3.329 V (0.010 V)
Current/Power -0.43 A (-22 W) Runtime 15d 22h 37m to empty
Remain Capacity/Energy 163.0 Ah (8.3 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 81.5 % State Of Health 100.0 %
Temperature 22.0 °C Cycle 66
MOSFET CFET = ON, DFET = ON Reported 2022-05-29 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.321 V 3.320 V 3.322 V 3.322 V 3.323 V 3.324 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.326 V 3.325 V 3.327 V 3.327 V 3.329 V 3.328 V 3.328 V
pack voltage and current cell voltages
pack temperature
Voltage 53.23 V Cell (MIN/MAX) 3.325 V / 3.326 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 95.3 Ah (4.9 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 95.3 % State Of Health 100.0 %
Temperature 22.0 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-29 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.325 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.26 V Cell (MIN/MAX) 3.328 V / 3.329 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 93.6 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.6 % State Of Health 100.0 %
Temperature 23.2 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-29 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.328 V 3.328 V 3.328 V 3.328 V 3.329 V 3.328 V 3.328 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.328 V 3.328 V 3.328 V 3.328 V 3.328 V 3.328 V 3.328 V
pack voltage and current cell voltages
pack temperature
Voltage 53.22 V Cell (MIN/MAX) 3.325 V / 3.326 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 94.2 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 94.2 % State Of Health 100.0 %
Temperature 23.3 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-29 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.326 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.23 V Cell (MIN/MAX) 3.326 V / 3.326 V (0.000 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 93.4 Ah (4.8 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 93.7 % State Of Health 99.7 %
Temperature 22.1 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-05-29 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
pack voltage and current cell voltages
pack temperature