Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.685 kW
07/01/2025 04:51 (1861 days) Production Consumption NET Usage
Now 0.000 kW 0.685 kW 0.685 kW
Today 0.000 kWh (0.000 kW) 4.213 kWh (0.864 kW) 4.213 kWh (0.864 kW)
  - This Week 57.286 kWh (26.011 kWh/day) 71.895 kWh (32.645 kWh/day) 14.609 kWh (6.633 kWh/day)
  - This Month 0.000 kWh (0.000 kWh/day) 4.213 kWh (20.741 kWh/day) 4.213 kWh (20.741 kWh/day)
  - This Year 3.030 MWh (16.720 kWh/day) 3.131 MWh (17.281 kWh/day) 0.102 MWh (0.561 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.451 kW/day) 35.083 MWh (18.850 kW/day) 2.603 MWh (1.398 kW/day)
Lifetime Since Install 32.515 MWh 35.663 MWh 3.149 MWh
Voltage/Current 251.7 V / 0.0 A 251.7 V / 2.7 A 251.7 V / 2.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/29/2022 22:41 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.787 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.124 0.405 0.783 5.329 0.000 kW
0.394 kWh
0.000 kW
2.362 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.120 0.379 0.743 5.065
03 - 202224****** IQ7+M [0] ---- 0.000 0.123 0.409 0.790 5.281
04 - 202232****** IQ7+ [0] ---- 0.000 0.122 0.397 0.778 5.198
05 - 202244****** IQ7+M [0] ---- 0.000 0.123 0.388 0.782 5.227
06 - 202245****** IQ7+M [0] ---- 0.000 0.120 0.384 0.754 5.091
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.163 0.409 0.797 5.440 0.000 kW
0.410 kWh
0.000 kW
2.052 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.166 0.414 0.927 6.187
09 - 202217****** IQ7+ [0] ---- 0.000 0.165 0.413 0.946 6.312
10 - 202244****** IQ7+M [0] ---- 0.000 0.168 0.416 0.965 6.497
11 - 202224****** IQ7+M [0] ---- 0.000 0.128 0.400 0.924 6.133
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.075 0.340 0.373 2.286 0.000 kW
0.343 kWh
0.000 kW
1.373 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.076 0.346 0.399 2.563
14 - 202216****** IQ7+ [0] ---- 0.000 0.077 0.347 0.412 2.582
15 - 202245****** IQ7+M [0] ---- 0.000 0.076 0.340 0.389 2.485
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.