Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 5.361 kW
03/17/2026 18:03 (2120 days) Production Consumption NET Usage
Now 1.194 kW 6.555 kW 5.361 kW
Today 30.284 kWh (1.677 kW) 24.195 kWh (1.340 kW) -6.089 kWh (-0.337 kW)
  - This Week 47.388 kWh (17.217 kWh/day) 51.305 kWh (18.640 kWh/day) 3.917 kWh (1.423 kWh/day)
  - This Month 282.109 kWh (16.840 kWh/day) 255.332 kWh (15.241 kWh/day) -26.777 kWh (-1.598 kWh/day)
  - This Year 0.916 MWh (12.092 kWh/day) 1.355 MWh (17.889 kWh/day) 0.439 MWh (5.797 kWh/day)
Yesterday 5.215 kWh (0.217 kW) 14.236 kWh (0.593 kW) 9.021 kWh (0.376 kW)
Last 7 Days 128.610 kWh (18.373 kWh/day) 110.288 kWh (15.755 kWh/day) -18.322 kWh (-2.617 kWh/day)
Last 30 Days (02/15/2026) 388.126 kWh (12.938 kWh/day) 450.866 kWh (15.029 kWh/day) 62.740 kWh (2.091 kWh/day)
Last One Year 6.050 MWh (16.576 kWh/day) 7.838 MWh (21.473 kWh/day) 1.788 MWh (4.898 kWh/day)
Lifetime Since PTO 36.482 MWh (17.202 kW/day) 40.866 MWh (19.270 kW/day) 4.384 MWh (2.067 kW/day)
Lifetime Since Install 36.516 MWh 41.446 MWh 4.930 MWh
Voltage/Current 246.5 V / 4.8 A 246.6 V / 26.6 A 246.5 V / 21.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/21/2023 23:28 (13.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.484 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.256 1.519 1.961 10.218 0.000 kW
1.473 kWh
0.000 kW
8.838 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.245 1.441 1.838 9.688
03 - 202224****** IQ7+M [5] VCOP 0.000 0.253 1.490 1.915 10.000
04 - 202232****** IQ7+ [5] VCOP 0.000 0.253 1.499 1.958 10.184
05 - 202244****** IQ7+M [5] VCOP 0.000 0.239 1.419 1.744 9.370
06 - 202245****** IQ7+M [5] VCOP 0.000 0.244 1.470 1.852 9.840
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.237 1.487 1.848 9.721 0.000 kW
1.480 kWh
0.000 kW
7.401 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.235 1.460 1.877 9.635
09 - 202217****** IQ7+ [5] VCOP 0.000 0.234 1.461 1.871 9.624
10 - 202244****** IQ7+M [5] VCOP 0.000 0.231 1.486 1.877 9.790
11 - 202224****** IQ7+M [5] VCOP 0.000 0.235 1.507 1.913 9.981
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.232 1.241 1.743 8.778 0.000 kW
1.278 kWh
0.000 kW
5.113 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.236 1.254 1.753 8.841
14 - 202216****** IQ7+ [5] VCOP 0.000 0.243 1.309 1.806 9.177
15 - 202245****** IQ7+M [5] VCOP 0.000 0.239 1.309 1.806 9.187
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.566 kWh
0.000 kW
1.133 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.230 1.133 1.137 7.873
Panel Layout Each Group Production