Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.838 kW
03/14/2026 09:09 (2117 days) Production Consumption NET Usage
Now 1.241 kW 0.403 kW -0.838 kW
Today 3.577 kWh (0.391 kW) 5.235 kWh (0.572 kW) 1.658 kWh (0.181 kW)
  - This Week 110.411 kWh (17.301 kWh/day) 87.843 kWh (13.765 kWh/day) -22.568 kWh (-3.536 kWh/day)
  - This Month 204.119 kWh (15.254 kWh/day) 194.142 kWh (14.508 kWh/day) -9.977 kWh (-0.746 kWh/day)
  - This Year 0.838 MWh (11.578 kWh/day) 1.294 MWh (17.877 kWh/day) 0.456 MWh (6.299 kWh/day)
Yesterday 20.551 kWh (0.855 kW) 13.313 kWh (0.554 kW) -7.238 kWh (-0.301 kW)
Last 7 Days 116.303 kWh (16.615 kWh/day) 99.771 kWh (14.253 kWh/day) -16.532 kWh (-2.362 kWh/day)
Last 30 Days (02/12/2026) 399.204 kWh (13.307 kWh/day) 498.937 kWh (16.631 kWh/day) 99.733 kWh (3.324 kWh/day)
Last One Year 6.040 MWh (16.548 kWh/day) 7.831 MWh (21.456 kWh/day) 1.791 MWh (4.907 kWh/day)
Lifetime Since PTO 36.404 MWh (17.193 kW/day) 40.805 MWh (19.271 kW/day) 4.401 MWh (2.079 kW/day)
Lifetime Since Install 36.438 MWh 41.385 MWh 4.947 MWh
Voltage/Current 251.3 V / 4.9 A 251.3 V / 1.6 A 251.3 V / -3.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/12/2025 23:47 (17.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.507 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.212 1.024 0.983 4.947 0.000 kW
1.006 kWh
0.000 kW
6.038 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.980 0.941 4.711
03 - 202224****** IQ7+M [5] VCOP 0.000 0.210 1.019 0.994 4.958
04 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.031 1.004 4.990
05 - 202244****** IQ7+M [5] VCOP 0.000 0.204 0.986 0.933 4.699
06 - 202245****** IQ7+M [5] VCOP 0.000 0.207 0.997 0.939 4.784
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.270 1.038 1.067 4.849 0.000 kW
1.218 kWh
0.000 kW
6.089 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.226 1.171 5.554
09 - 202217****** IQ7+ [5] VCOP 0.000 0.277 1.334 1.214 5.863
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.296 1.209 5.795
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.194 1.166 5.443
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.072 0.297 0.438 2.500 0.000 kW
0.366 kWh
0.000 kW
1.462 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.085 0.380 0.509 2.784
14 - 202216****** IQ7+ [5] VCOP 0.000 0.089 0.399 0.527 2.906
15 - 202245****** IQ7+M [5] VCOP 0.000 0.087 0.386 0.528 2.885
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.959 kWh
0.000 kW
1.918 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.230 1.918 4.792 21.541
Panel Layout Each Group Production

Charger History
Voltage PV 0.37 V Voltage Charge 52.44 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.8 °C / 23.7 °C Flags 00/00/00 Energy Today 5.378 kWh @ 2025-12-12 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.62 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 185.1 Ah (9.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 31.2 % State Of Health 98.9 %
Run Time 5d 3h 24m to empty Report Date 2025-12-12 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.