Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.420 kW
11/04/2025 21:10 (1987 days) Production Consumption NET Usage
Now 0.000 kW 0.420 kW 0.420 kW
Today 17.563 kWh (0.828 kW) 14.342 kWh (0.677 kW) -3.221 kWh (-0.152 kW)
  - This Week 41.380 kWh (14.354 kWh/day) 54.771 kWh (18.999 kWh/day) 13.391 kWh (4.645 kWh/day)
  - This Month 58.318 kWh (15.018 kWh/day) 70.959 kWh (18.273 kWh/day) 12.641 kWh (3.255 kWh/day)
  - This Year 5.636 MWh (18.306 kWh/day) 6.403 MWh (20.798 kWh/day) 0.767 MWh (2.492 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.087 MWh (17.650 kW/day) 38.356 MWh (19.295 kW/day) 3.269 MWh (1.644 kW/day)
Lifetime Since Install 35.121 MWh 38.936 MWh 3.815 MWh
Voltage/Current 250.1 V / 0.0 A 250.1 V / 1.7 A 250.1 V / 1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/23/2023 23:21 (14.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.880 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.286 2.137 1.789 12.964 0.000 kW
2.079 kWh
0.000 kW
12.473 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.272 2.037 1.686 12.208
03 - 202224****** IQ7+M [0] ---- 0.000 0.281 2.097 1.740 12.540
04 - 202232****** IQ7+ [0] ---- 0.000 0.290 2.143 1.771 12.776
05 - 202244****** IQ7+M [0] ---- 0.000 0.273 1.970 1.579 11.500
06 - 202245****** IQ7+M [0] ---- 0.000 0.277 2.089 1.729 12.534
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.287 2.042 1.612 11.945 0.000 kW
2.038 kWh
0.000 kW
10.188 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.286 1.996 1.622 11.724
09 - 202217****** IQ7+ [0] ---- 0.000 0.287 2.025 1.620 11.878
10 - 202244****** IQ7+M [0] ---- 0.000 0.284 2.045 1.619 12.018
11 - 202224****** IQ7+M [0] ---- 0.000 0.288 2.080 1.638 12.177
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.249 1.829 1.706 12.165 0.000 kW
1.883 kWh
0.000 kW
7.530 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.254 1.839 1.753 12.237
14 - 202216****** IQ7+ [0] ---- 0.000 0.257 1.928 1.802 12.735
15 - 202245****** IQ7+M [0] ---- 0.000 0.260 1.934 1.810 12.755
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.688 1.689 11.837 0.000 kW
1.688 kWh
0.000 kW
1.688 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.58 V Current/Power -3.53 A (-0.186 kW)
Remain Capacity/Energy 289.0 Ah (14.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 48.2 % State Of Health 100.0 %
Run Time 3d 9h 51m to empty Report Date 2023-05-23 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.58 V Cell (MIN/MAX) 3.280 V / 3.291 V (0.011 V)
Current/Power -1.06 A (-55 W) Runtime 3d 19h 2m to empty
Remain Capacity/Energy 96.3 Ah (4.9 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 48.2 % State Of Health 100.0 %
Temperature 22.0 °C Cycle 101
MOSFET CFET = ON, DFET = ON Reported 2023-05-23 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.280 V 3.281 V 3.281 V 3.283 V 3.284 V 3.283 V 3.284 V 3.285 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.287 V 3.287 V 3.287 V 3.288 V 3.289 V 3.291 V 3.291 V 3.290 V
pack voltage and current cell voltages
pack temperature