Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.484 kW
12/30/2025 05:32 (2043 days) Production Consumption NET Usage
Now 0.000 kW 0.484 kW 0.484 kW
Today 0.000 kWh (0.000 kW) 2.308 kWh (0.415 kW) 2.308 kWh (0.415 kW)
  - This Week 2.190 kWh (0.981 kWh/day) 82.910 kWh (37.155 kWh/day) 80.720 kWh (36.174 kWh/day)
  - This Month 226.791 kWh (7.758 kWh/day) 612.292 kWh (20.946 kWh/day) 385.501 kWh (13.188 kWh/day)
  - This Year 6.096 MWh (16.782 kWh/day) 7.529 MWh (20.727 kWh/day) 1.433 MWh (3.945 kWh/day)
Yesterday 0.318 kWh (0.013 kW) 16.224 kWh (0.676 kW) 15.906 kWh (0.663 kW)
Last 7 Days 29.385 kWh (4.198 kWh/day) 156.335 kWh (22.334 kWh/day) 126.950 kWh (18.136 kWh/day)
Last 30 Days 228.082 kWh (7.603 kWh/day) 627.992 kWh (20.933 kWh/day) 399.910 kWh (13.331 kWh/day)
Last One Year 6.119 MWh (16.764 kWh/day) 7.563 MWh (20.721 kWh/day) 1.444 MWh (3.957 kWh/day)
Lifetime Since PTO 35.547 MWh (17.397 kW/day) 39.481 MWh (19.323 kW/day) 3.935 MWh (1.926 kW/day)
Lifetime Since Install 35.581 MWh 40.061 MWh 4.481 MWh
Voltage/Current 249.2 V / 0.0 A 249.3 V / 1.9 A 249.2 V / 1.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/24/2023 23:28 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.582 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.971 1.930 11.809 0.000 kW
1.931 kWh
0.000 kW
11.584 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.287 1.882 1.795 11.118
03 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.951 1.835 11.430
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.975 1.882 11.608
05 - 202244****** IQ7+M [0] ---- 0.000 0.288 1.878 1.633 10.461
06 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.927 1.849 11.396
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.947 1.713 10.820 0.000 kW
1.932 kWh
0.000 kW
9.662 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.886 1.722 10.670
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 1.918 1.704 10.744
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.940 1.710 10.840
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.972 1.746 10.998
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.261 1.594 1.914 10.857 0.000 kW
1.635 kWh
0.000 kW
6.539 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.274 1.585 1.932 11.006
14 - 202216****** IQ7+ [0] ---- 0.000 0.276 1.676 1.978 11.388
15 - 202245****** IQ7+M [0] ---- 0.000 0.278 1.684 1.988 11.433
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.898 kWh
0.000 kW
1.796 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.796 2.122 9.831
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.