Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.647 kW
05/30/2026 10:06 (2194 days) Production Consumption NET Usage
Now 1.945 kW 0.298 kW -1.647 kW
Today 6.605 kWh (0.652 kW) 5.023 kWh (0.496 kW) -1.582 kWh (-0.156 kW)
  - This Week 165.220 kWh (25.729 kWh/day) 145.737 kWh (22.695 kWh/day) -19.483 kWh (-3.034 kWh/day)
  - This Month 727.215 kWh (24.717 kWh/day) 501.906 kWh (17.059 kWh/day) -225.309 kWh (-7.658 kWh/day)
  - This Year 2.680 MWh (17.937 kWh/day) 2.562 MWh (17.144 kWh/day) -0.119 MWh (-0.794 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 168.816 kWh (24.117 kWh/day) 152.189 kWh (21.741 kWh/day) -16.627 kWh (-2.375 kWh/day)
Last 30 Days (04/30/2026) 735.431 kWh (24.514 kWh/day) 508.290 kWh (16.943 kWh/day) -227.141 kWh (-7.571 kWh/day)
Last One Year 6.431 MWh (17.620 kWh/day) 7.836 MWh (21.469 kWh/day) 1.405 MWh (3.848 kWh/day)
Lifetime Since PTO 38.246 MWh (17.429 kW/day) 42.072 MWh (19.172 kW/day) 3.826 MWh (1.744 kW/day)
Lifetime Since Install 38.280 MWh 42.652 MWh 4.373 MWh
Voltage/Current 249.4 V / 7.8 A 249.4 V / 1.2 A 249.4 V / -6.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/30/2023 23:58 (8.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.896 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.105 0.276 0.672 2.142 0.000 kW
0.265 kWh
0.000 kW
1.589 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.096 0.257 0.642 2.006
03 - 202224****** IQ7+M [5] VCOP 0.000 0.102 0.273 0.672 2.132
04 - 202232****** IQ7+ [5] VCOP 0.000 0.104 0.270 0.677 2.132
05 - 202244****** IQ7+M [5] VCOP 0.000 0.098 0.251 0.651 1.997
06 - 202245****** IQ7+M [5] VCOP 0.000 0.100 0.261 0.649 2.039
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.090 0.257 0.685 2.018 0.000 kW
0.265 kWh
0.000 kW
1.327 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.105 0.269 0.810 2.244
09 - 202217****** IQ7+ [5] VCOP 0.000 0.104 0.269 0.810 2.233
10 - 202244****** IQ7+M [5] VCOP 0.000 0.104 0.268 0.810 2.230
11 - 202224****** IQ7+M [5] VCOP 0.000 0.102 0.263 0.801 2.221
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.079 0.223 0.287 1.466 0.000 kW
0.245 kWh
0.000 kW
0.980 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.084 0.240 0.335 1.609
14 - 202216****** IQ7+ [5] VCOP 0.000 0.088 0.258 0.354 1.703
15 - 202245****** IQ7+M [5] VCOP 0.000 0.086 0.259 0.351 1.695
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.16 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 507.9 Ah (26.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 85.6 % State Of Health 98.9 %
Run Time 14d 2h 36m to empty Report Date 2023-12-30 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.