Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 6.041 kW
04/10/2026 03:01 (2144 days) Production Consumption NET Usage
Now 0.317 kW 6.358 kW 6.041 kW
Today 0.966 kWh (0.316 kW) 18.461 kWh (6.048 kW) 17.495 kWh (5.732 kW)
  - This Week 150.842 kWh (29.427 kWh/day) 88.450 kWh (17.255 kWh/day) -62.392 kWh (-12.172 kWh/day)
  - This Month 203.447 kWh (22.293 kWh/day) 149.509 kWh (16.383 kWh/day) -53.938 kWh (-5.910 kWh/day)
  - This Year 1.433 MWh (14.455 kWh/day) 1.715 MWh (17.300 kWh/day) 0.282 MWh (2.845 kWh/day)
Yesterday 38.872 kWh (1.622 kW) 13.357 kWh (0.557 kW) -25.515 kWh (-1.065 kW)
Last 7 Days 186.648 kWh (26.664 kWh/day) 116.655 kWh (16.665 kWh/day) -69.993 kWh (-9.999 kWh/day)
Last 30 Days (03/11/2026) 645.314 kWh (21.510 kWh/day) 465.109 kWh (15.504 kWh/day) -180.205 kWh (-6.007 kWh/day)
Last One Year 6.177 MWh (16.924 kWh/day) 7.849 MWh (21.503 kWh/day) 1.671 MWh (4.578 kWh/day)
Lifetime Since PTO 36.999 MWh (17.256 kW/day) 41.226 MWh (19.227 kW/day) 4.227 MWh (1.971 kW/day)
Lifetime Since Install 37.032 MWh 41.806 MWh 4.773 MWh
Voltage/Current 249.1 V / 1.3 A 249.1 V / 25.5 A 249.1 V / 24.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/12/2023 23:02 (9.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.953 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.252 1.071 1.012 4.849 0.000 kW
1.059 kWh
0.000 kW
6.352 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.244 1.028 0.962 4.604
03 - 202224****** IQ7+M [0] ---- 0.000 0.250 1.074 1.008 4.803
04 - 202232****** IQ7+ [0] ---- 0.000 0.251 1.081 1.016 4.825
05 - 202244****** IQ7+M [0] ---- 0.000 0.244 1.045 0.987 4.655
06 - 202245****** IQ7+M [0] ---- 0.000 0.251 1.053 1.004 4.751
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.135 0.992 4.911 0.000 kW
1.256 kWh
0.000 kW
6.281 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.227 1.135 5.445
09 - 202217****** IQ7+ [0] ---- 0.000 0.294 1.355 1.286 5.927
10 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.308 1.241 5.792
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.256 1.169 5.614
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.129 0.512 0.517 2.833 0.000 kW
0.580 kWh
0.000 kW
2.321 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.136 0.581 0.579 3.123
14 - 202216****** IQ7+ [0] ---- 0.000 0.138 0.618 0.601 3.284
15 - 202245****** IQ7+M [0] ---- 0.000 0.137 0.609 0.593 3.259
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 5.841
Panel Layout Each Group Production

Battery History
Voltage 53.33 V Current/Power -0.60 A (-31 W)
Remain Capacity/Energy 396.9 Ah (20.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 66.9 % State Of Health 98.9 %
Run Time 27d 13h 29m to empty Report Date 2023-11-12 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.