Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.321 kW
06/27/2026 19:12 (2222 days) Production Consumption NET Usage
Now 0.169 kW 0.490 kW 0.321 kW
Today 9.900 kWh (0.515 kW) 11.469 kWh (0.596 kW) 1.569 kWh (0.082 kW)
  - This Week 134.063 kWh (19.713 kWh/day) 150.355 kWh (22.109 kWh/day) 16.292 kWh (2.396 kWh/day)
  - This Month 793.709 kWh (29.614 kWh/day) 637.211 kWh (23.775 kWh/day) -156.498 kWh (-5.839 kWh/day)
  - This Year 3.528 MWh (19.843 kWh/day) 3.207 MWh (18.038 kWh/day) -0.321 MWh (-1.805 kWh/day)
Yesterday 18.889 kWh (0.787 kW) 17.732 kWh (0.739 kW) -1.157 kWh (-0.048 kW)
Last 7 Days 134.306 kWh (19.187 kWh/day) 154.713 kWh (22.102 kWh/day) 20.407 kWh (2.915 kWh/day)
Last 30 Days (05/28/2026) 893.177 kWh (29.773 kWh/day) 715.715 kWh (23.857 kWh/day) -177.462 kWh (-5.915 kWh/day)
Last One Year 6.692 MWh (18.333 kWh/day) 7.734 MWh (21.190 kWh/day) 1.043 MWh (2.856 kWh/day)
Lifetime Since PTO 39.094 MWh (17.588 kW/day) 42.718 MWh (19.218 kW/day) 3.624 MWh (1.630 kW/day)
Lifetime Since Install 39.128 MWh 43.298 MWh 4.170 MWh
Voltage/Current 249.7 V / 0.7 A 249.6 V / 2.0 A 249.7 V / 1.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/31/2026 23:28 (12.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.698 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.256 1.264 1.861 11.990 0.000 kW
1.234 kWh
0.000 kW
7.407 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.246 1.217 1.773 11.512
03 - 202224****** IQ7+M [5] VCOP 0.000 0.249 1.265 1.839 11.977
04 - 202232****** IQ7+ [5] VCOP 0.000 0.263 1.252 1.833 11.929
05 - 202244****** IQ7+M [5] VCOP 0.000 0.241 1.186 1.743 11.243
06 - 202245****** IQ7+M [5] VCOP 0.000 0.247 1.222 1.788 11.475
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.269 1.269 1.800 11.679 0.000 kW
1.295 kWh
0.000 kW
6.477 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.287 1.914 12.317
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.277 1.915 12.234
10 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.319 1.910 12.431
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.324 1.930 12.531
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.202 1.034 1.400 9.284 0.000 kW
1.069 kWh
0.000 kW
4.275 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.203 1.060 1.403 9.379
14 - 202216****** IQ7+ [5] VCOP 0.000 0.206 1.087 1.454 9.731
15 - 202245****** IQ7+M [5] VCOP 0.000 0.209 1.094 1.454 9.741
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.180 kWh
0.000 kW
0.540 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.128 0.540 0.680 5.242
Panel Layout Each Group Production

Charger History
Voltage PV 1.43 V Voltage Charge 52.52 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 24.6 °C / 23.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-03-31 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.69 V Current/Power -1.62 A (-85 W)
Remain Capacity/Energy 181.2 Ah (9.3 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 33.1 % State Of Health 91.4 %
Run Time 4d 15h 51m to empty Report Date 2026-03-31 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.