Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.479 kW
11/27/2025 14:10 (2010 days) Production Consumption NET Usage
Now 2.338 kW 0.859 kW -1.479 kW
Today 11.854 kWh (0.837 kW) 7.200 kWh (0.508 kW) -4.654 kWh (-0.328 kW)
  - This Week 39.332 kWh (8.568 kWh/day) 62.857 kWh (13.693 kWh/day) 23.525 kWh (5.125 kWh/day)
  - This Month 260.611 kWh (9.801 kWh/day) 479.572 kWh (18.035 kWh/day) 218.961 kWh (8.234 kWh/day)
  - This Year 5.839 MWh (17.661 kWh/day) 6.812 MWh (20.605 kWh/day) 0.973 MWh (2.944 kWh/day)
Yesterday 2.966 kWh (0.124 kW) 14.109 kWh (0.588 kW) 11.143 kWh (0.464 kW)
Last 7 Days 47.683 kWh (6.812 kWh/day) 100.026 kWh (14.289 kWh/day) 52.343 kWh (7.478 kWh/day)
Last 30 Days 282.082 kWh (9.403 kWh/day) 526.682 kWh (17.556 kWh/day) 244.600 kWh (8.153 kWh/day)
Last One Year 6.123 MWh (16.775 kWh/day) 7.478 MWh (20.487 kWh/day) 1.355 MWh (3.712 kWh/day)
Lifetime Since PTO 35.289 MWh (17.551 kW/day) 38.765 MWh (19.280 kW/day) 3.475 MWh (1.728 kW/day)
Lifetime Since Install 35.323 MWh 39.345 MWh 4.021 MWh
Voltage/Current 249.6 V / 9.4 A 249.7 V / 3.4 A 249.7 V / -5.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/23/2023 23:34 (14.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.454 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.930 2.120 10.414 0.000 kW
1.821 kWh
0.000 kW
10.925 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.795 1.969 9.831
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.835 2.011 10.125
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.882 2.060 10.258
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.633 1.806 9.325
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.849 2.036 10.064
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.713 1.903 9.586 0.000 kW
1.719 kWh
0.000 kW
8.595 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.722 1.867 9.430
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.704 1.888 9.524
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.710 1.901 9.615
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.746 1.940 9.736
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.252 1.914 2.068 9.429 0.000 kW
1.953 kWh
0.000 kW
7.812 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.257 1.932 2.072 9.580
14 - 202216****** IQ7+ [5] VCOP 0.000 0.258 1.978 2.123 9.948
15 - 202245****** IQ7+M [5] VCOP 0.000 0.259 1.988 2.131 9.986
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 2.122 2.036 8.919 0.000 kW
2.122 kWh
0.000 kW
2.122 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.