Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.687 kW
12/15/2025 12:57 (2028 days) Production Consumption NET Usage
Now 0.974 kW 0.287 kW -0.687 kW
Today 5.105 kWh (0.394 kW) 5.879 kWh (0.453 kW) 0.774 kWh (0.060 kW)
  - This Week 5.405 kWh (3.508 kWh/day) 22.869 kWh (14.842 kWh/day) 17.464 kWh (11.334 kWh/day)
  - This Month 126.156 kWh (8.676 kWh/day) 284.142 kWh (19.542 kWh/day) 157.986 kWh (10.866 kWh/day)
  - This Year 5.995 MWh (17.201 kWh/day) 7.200 MWh (20.659 kWh/day) 1.205 MWh (3.458 kWh/day)
Yesterday 0.300 kWh (0.012 kW) 16.990 kWh (0.708 kW) 16.690 kWh (0.695 kW)
Last 7 Days 59.809 kWh (8.545 kWh/day) 178.180 kWh (25.456 kWh/day) 118.371 kWh (16.912 kWh/day)
Last 30 Days 266.149 kWh (8.872 kWh/day) 560.724 kWh (18.691 kWh/day) 294.575 kWh (9.819 kWh/day)
Last One Year 6.101 MWh (16.715 kWh/day) 7.574 MWh (20.751 kWh/day) 1.473 MWh (4.036 kWh/day)
Lifetime Since PTO 35.446 MWh (17.473 kW/day) 39.153 MWh (19.301 kW/day) 3.707 MWh (1.827 kW/day)
Lifetime Since Install 35.480 MWh 39.733 MWh 4.253 MWh
Voltage/Current 248.8 V / 3.9 A 248.7 V / 1.2 A 248.8 V / -2.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/22/2025 23:56 (23.7 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 20.260 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.242 1.040 1.543 10.318 0.000 kW
1.017 kWh
0.000 kW
6.101 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.231 0.991 1.484 9.879
03 - 202224****** IQ7+M [5] VCOP 0.000 0.240 1.031 1.541 10.242
04 - 202232****** IQ7+ [5] VCOP 0.000 0.245 1.039 1.554 10.316
05 - 202244****** IQ7+M [5] VCOP 0.000 0.233 0.986 1.449 9.593
06 - 202245****** IQ7+M [5] VCOP 0.000 0.239 1.013 1.485 9.825
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.270 1.048 1.551 9.761 0.000 kW
1.064 kWh
0.000 kW
5.321 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.062 1.631 10.561
09 - 202217****** IQ7+ [5] VCOP 0.000 0.274 1.066 1.631 10.537
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 1.067 1.636 10.542
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.078 1.647 10.690
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.148 0.794 1.138 8.008 0.000 kW
0.835 kWh
0.000 kW
3.339 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.152 0.827 1.165 8.166
14 - 202216****** IQ7+ [5] VCOP 0.000 0.154 0.857 1.211 8.460
15 - 202245****** IQ7+M [5] VCOP 0.000 0.157 0.861 1.210 8.459
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.750 kWh
0.230 kW
5.500 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.500 5.557 38.541
Panel Layout Each Group Production

Charger History
Voltage PV 0.59 V Voltage Charge 52.16 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.1 °C / 27.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-22 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.44 V Current/Power -6.35 A (-0.333 kW)
Remain Capacity/Energy 190.8 Ah (9.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 32.2 % State Of Health 98.9 %
Run Time 1d 6h 3m to empty Report Date 2025-09-22 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.