Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.542 kW
01/22/2026 13:55 (2066 days) Production Consumption NET Usage
Now 2.707 kW 0.165 kW -2.542 kW
Today 9.696 kWh (0.696 kW) 7.540 kWh (0.541 kW) -2.156 kWh (-0.155 kW)
  - This Week 41.705 kWh (9.103 kWh/day) 108.704 kWh (23.728 kWh/day) 66.999 kWh (14.625 kWh/day)
  - This Month 181.125 kWh (8.393 kWh/day) 414.890 kWh (19.225 kWh/day) 233.765 kWh (10.832 kWh/day)
  - This Year 0.181 MWh (8.393 kWh/day) 0.415 MWh (19.225 kWh/day) 0.234 MWh (10.832 kWh/day)
Yesterday 13.006 kWh (0.542 kW) 16.553 kWh (0.689 kW) 3.547 kWh (0.148 kW)
Last 7 Days 55.746 kWh (7.963 kWh/day) 154.710 kWh (22.099 kWh/day) 98.964 kWh (14.136 kWh/day)
Last 30 Days 219.850 kWh (7.328 kWh/day) 596.093 kWh (19.870 kWh/day) 376.243 kWh (12.541 kWh/day)
Last One Year 6.107 MWh (16.731 kWh/day) 7.433 MWh (20.363 kWh/day) 1.326 MWh (3.632 kWh/day)
Lifetime Since PTO 35.747 MWh (17.297 kW/day) 39.926 MWh (19.320 kW/day) 4.180 MWh (2.022 kW/day)
Lifetime Since Install 35.781 MWh 40.506 MWh 4.726 MWh
Voltage/Current 250.1 V / 10.8 A 249.9 V / 0.7 A 250.0 V / -10.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/13/2023 23:49 (9.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.247 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.218 1.057 1.069 5.168 0.000 kW
1.031 kWh
0.000 kW
6.183 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.207 1.006 1.027 4.914
03 - 202224****** IQ7+M [5] VCOP 0.000 0.214 1.041 1.073 5.123
04 - 202232****** IQ7+ [5] VCOP 0.000 0.216 1.046 1.080 5.149
05 - 202244****** IQ7+M [5] VCOP 0.000 0.209 1.009 1.045 4.979
06 - 202245****** IQ7+M [5] VCOP 0.000 0.207 1.024 1.053 5.057
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.267 1.023 1.128 5.161 0.000 kW
1.172 kWh
0.000 kW
5.862 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.266 1.177 1.225 5.754
09 - 202217****** IQ7+ [5] VCOP 0.000 0.265 1.252 1.349 6.310
10 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.230 1.307 6.144
11 - 202224****** IQ7+M [5] VCOP 0.000 0.265 1.181 1.254 5.916
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.106 0.483 0.511 2.873 0.000 kW
0.550 kWh
0.000 kW
2.201 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.112 0.561 0.582 3.192
14 - 202216****** IQ7+ [5] VCOP 0.000 0.114 0.583 0.618 3.366
15 - 202245****** IQ7+M [5] VCOP 0.000 0.113 0.574 0.610 3.338
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.135
Panel Layout Each Group Production