Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.686 kW
07/01/2025 20:48 (1861 days) Production Consumption NET Usage
Now 0.000 kW 0.686 kW 0.686 kW
Today 20.982 kWh (1.007 kW) 28.259 kWh (1.356 kW) 7.277 kWh (0.349 kW)
  - This Week 78.268 kWh (27.297 kWh/day) 95.941 kWh (33.460 kWh/day) 17.673 kWh (6.164 kWh/day)
  - This Month 20.982 kWh (24.170 kWh/day) 28.259 kWh (32.553 kWh/day) 7.277 kWh (8.383 kWh/day)
  - This Year 3.051 MWh (16.774 kWh/day) 3.155 MWh (17.351 kWh/day) 0.105 MWh (0.576 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.502 MWh (17.456 kW/day) 35.107 MWh (18.856 kW/day) 2.606 MWh (1.400 kW/day)
Lifetime Since Install 32.535 MWh 35.687 MWh 3.152 MWh
Voltage/Current 249.8 V / 0.0 A 249.7 V / 2.7 A 249.8 V / 2.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/13/2023 23:18 (14.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.999 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.241 1.520 1.992 14.702 0.000 kW
1.470 kWh
0.000 kW
8.822 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.226 1.442 1.848 13.762
03 - 202224****** IQ7+M [0] ---- 0.000 0.235 1.492 1.902 14.196
04 - 202232****** IQ7+ [0] ---- 0.000 0.238 1.495 1.942 14.468
05 - 202244****** IQ7+M [0] ---- 0.000 0.226 1.404 1.722 12.979
06 - 202245****** IQ7+M [0] V--- 0.000 0.233 1.469 1.900 14.084
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.234 1.400 1.803 13.685 0.000 kW
1.406 kWh
0.000 kW
7.030 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.226 1.399 1.762 13.484
09 - 202217****** IQ7+ [0] ---- 0.000 0.241 1.405 1.769 13.553
10 - 202244****** IQ7+M [0] ---- 0.000 0.227 1.407 1.813 13.733
11 - 202224****** IQ7+M [0] ---- 0.000 0.240 1.420 1.845 13.970
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.203 1.343 1.864 13.524 0.000 kW
1.398 kWh
0.000 kW
5.591 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.206 1.390 1.898 13.607
14 - 202216****** IQ7+ [0] ---- 0.000 0.214 1.428 1.940 14.105
15 - 202245****** IQ7+M [0] ---- 0.000 0.212 1.431 1.939 14.104
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.557 1.806 11.771 0.000 kW
1.557 kWh
0.000 kW
1.557 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.16 V Current/Power -6.31 A (-0.335 kW)
Remain Capacity/Energy 438.1 Ah (22.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 73.0 % State Of Health 100.0 %
Run Time 2d 21h 26m to empty Report Date 2023-05-13 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.