Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.407 kW
12/13/2025 05:58 (2026 days) Production Consumption NET Usage
Now 0.000 kW 0.407 kW 0.407 kW
Today 0.000 kWh (0.000 kW) 2.504 kWh (0.417 kW) 2.504 kWh (0.417 kW)
  - This Week 63.159 kWh (10.107 kWh/day) 114.181 kWh (18.271 kWh/day) 51.022 kWh (8.165 kWh/day)
  - This Month 115.981 kWh (9.468 kWh/day) 203.714 kWh (16.631 kWh/day) 87.733 kWh (7.162 kWh/day)
  - This Year 5.985 MWh (17.285 kWh/day) 7.120 MWh (20.563 kWh/day) 1.135 MWh (3.278 kWh/day)
Yesterday 13.593 kWh (0.567 kW) 13.730 kWh (0.573 kW) 0.137 kWh (0.006 kW)
Last 7 Days 72.074 kWh (10.297 kWh/day) 129.421 kWh (18.490 kWh/day) 57.347 kWh (8.193 kWh/day)
Last 30 Days 277.383 kWh (9.246 kWh/day) 557.231 kWh (18.575 kWh/day) 279.848 kWh (9.329 kWh/day)
Last One Year 6.124 MWh (16.777 kWh/day) 7.529 MWh (20.628 kWh/day) 1.405 MWh (3.851 kWh/day)
Lifetime Since PTO 35.436 MWh (17.488 kW/day) 39.073 MWh (19.283 kW/day) 3.637 MWh (1.795 kW/day)
Lifetime Since Install 35.470 MWh 39.653 MWh 4.183 MWh
Voltage/Current 250.2 V / 0.0 A 250.1 V / 1.6 A 250.2 V / 1.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/04/2023 23:55 (23.8 hours) Number of Devices 17 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 15.879 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.188 0.730 1.231 5.666 0.000 kW
0.717 kWh
0.000 kW
4.302 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.184 0.695 1.165 5.334
03 - 202224****** IQ7+M [0] ---- 0.000 0.189 0.730 1.209 5.496
04 - 202232****** IQ7+ [0] ---- 0.000 0.188 0.735 1.223 5.509
05 - 202244****** IQ7+M [0] ---- 0.000 0.185 0.697 1.185 5.387
06 - 202245****** IQ7+M [0] ---- 0.000 0.171 0.715 1.225 5.557
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.211 0.719 1.315 5.655 0.000 kW
0.757 kWh
0.000 kW
3.784 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.242 0.760 1.482 6.309
09 - 202217****** IQ7+ [0] ---- 0.000 0.206 0.773 1.589 6.674
10 - 202244****** IQ7+M [0] ---- 0.000 0.238 0.769 1.562 6.597
11 - 202224****** IQ7+M [0] ---- 0.000 0.243 0.764 1.541 6.506
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.132 0.535 0.603 3.263 0.000 kW
0.574 kWh
0.000 kW
2.297 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.133 0.568 0.693 3.601
14 - 202216****** IQ7+ [0] ---- 0.000 0.139 0.597 0.722 3.768
15 - 202245****** IQ7+M [0] ---- 0.000 0.140 0.597 0.716 3.748
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.748 kWh
0.229 kW
5.496 kWh
17 - 122214****** IQ7PD [0] ---- 0.229 0.231 5.496 5.511 9.162
Panel Layout Each Group Production

Battery History
Voltage 52.40 V Current/Power -5.98 A (-0.313 kW)
Remain Capacity/Energy 225.3 Ah (11.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 38.0 % State Of Health 98.9 %
Run Time 1d 13h 40m to empty Report Date 2023-11-04 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.