Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.135 kW
06/28/2026 17:35 (2223 days) Production Consumption NET Usage
Now 2.266 kW 2.401 kW 0.135 kW
Today 24.937 kWh (1.417 kW) 17.498 kWh (0.994 kW) -7.439 kWh (-0.423 kW)
  - This Week 24.937 kWh (34.002 kWh/day) 17.498 kWh (23.859 kWh/day) -7.439 kWh (-10.143 kWh/day)
  - This Month 818.764 kWh (29.521 kWh/day) 660.194 kWh (23.804 kWh/day) -158.570 kWh (-5.717 kWh/day)
  - This Year 3.553 MWh (19.880 kWh/day) 3.230 MWh (18.072 kWh/day) -0.323 MWh (-1.807 kWh/day)
Yesterday 10.018 kWh (0.417 kW) 16.954 kWh (0.706 kW) 6.936 kWh (0.289 kW)
Last 7 Days 132.931 kWh (18.990 kWh/day) 164.288 kWh (23.470 kWh/day) 31.357 kWh (4.480 kWh/day)
Last 30 Days (05/29/2026) 882.555 kWh (29.418 kWh/day) 678.930 kWh (22.631 kWh/day) -203.625 kWh (-6.787 kWh/day)
Last One Year 6.697 MWh (18.347 kWh/day) 7.740 MWh (21.205 kWh/day) 1.043 MWh (2.857 kWh/day)
Lifetime Since PTO 39.119 MWh (17.592 kW/day) 42.741 MWh (19.220 kW/day) 3.622 MWh (1.629 kW/day)
Lifetime Since Install 39.153 MWh 43.321 MWh 4.168 MWh
Voltage/Current 248.5 V / 9.1 A 248.4 V / 9.7 A 248.4 V / 0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/20/2024 23:20 (14.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.792 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 2.195 1.837 7.929 0.000 kW
2.076 kWh
0.000 kW
12.458 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.278 2.041 1.759 7.553
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 2.096 1.814 7.830
04 - 202232****** IQ7+ [5] VCOP 0.000 0.292 2.162 1.831 7.866
05 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.867 1.718 7.212
06 - 202245****** IQ7+M [5] VCOP 0.000 0.283 2.096 1.785 7.645
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 2.016 1.734 7.185 0.000 kW
1.995 kWh
0.000 kW
9.973 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.947 1.707 7.191
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 1.955 1.702 7.148
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 2.001 1.722 7.188
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.053 1.755 7.280
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.245 2.027 1.602 7.357 0.000 kW
2.090 kWh
0.000 kW
8.362 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.253 2.039 1.592 7.589
14 - 202216****** IQ7+ [5] VCOP 0.000 0.254 2.148 1.711 8.008
15 - 202245****** IQ7+M [5] VCOP 0.000 0.253 2.148 1.704 7.989
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.19 V Current/Power -1.47 A (-78 W)
Remain Capacity/Energy 545.4 Ah (27.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 92.0 % State Of Health 98.9 %
Run Time 15d 11h 1m to empty Report Date 2024-05-20 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.