Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.152 kW
06/28/2026 19:04 (2223 days) Production Consumption NET Usage
Now 0.414 kW 0.566 kW 0.152 kW
Today 26.782 kWh (1.404 kW) 21.238 kWh (1.113 kW) -5.544 kWh (-0.291 kW)
  - This Week 26.782 kWh (33.695 kWh/day) 21.238 kWh (26.720 kWh/day) -5.544 kWh (-6.975 kWh/day)
  - This Month 820.609 kWh (29.523 kWh/day) 663.934 kWh (23.886 kWh/day) -156.675 kWh (-5.637 kWh/day)
  - This Year 3.555 MWh (19.883 kWh/day) 3.234 MWh (18.087 kWh/day) -0.321 MWh (-1.796 kWh/day)
Yesterday 10.018 kWh (0.417 kW) 16.954 kWh (0.706 kW) 6.936 kWh (0.289 kW)
Last 7 Days 132.923 kWh (18.989 kWh/day) 165.350 kWh (23.621 kWh/day) 32.427 kWh (4.632 kWh/day)
Last 30 Days (05/29/2026) 883.022 kWh (29.434 kWh/day) 681.426 kWh (22.714 kWh/day) -201.596 kWh (-6.720 kWh/day)
Last One Year 6.698 MWh (18.349 kWh/day) 7.740 MWh (21.206 kWh/day) 1.043 MWh (2.857 kWh/day)
Lifetime Since PTO 39.121 MWh (17.592 kW/day) 42.745 MWh (19.221 kW/day) 3.624 MWh (1.630 kW/day)
Lifetime Since Install 39.155 MWh 43.325 MWh 4.170 MWh
Voltage/Current 249.3 V / 1.7 A 249.3 V / 2.3 A 249.3 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/29/2024 23:53 (13.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 19.325 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.376 1.710 10.031 0.000 kW
1.335 kWh
0.000 kW
8.009 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.269 1.308 1.601 9.436
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.359 1.653 9.762
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.368 1.688 9.902
05 - 202244****** IQ7+M [5] VCOP 0.000 0.288 1.263 1.482 8.914
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.334 1.633 9.612
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.314 1.526 9.193 0.000 kW
1.307 kWh
0.000 kW
6.534 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.282 1.547 9.148
09 - 202217****** IQ7+ [5] VCOP 0.000 0.288 1.290 1.532 9.137
10 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.315 1.527 9.192
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.334 1.549 9.326
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.258 1.146 1.650 9.249 0.000 kW
1.195 kWh
0.000 kW
4.782 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.234 1.161 1.697 9.512
14 - 202216****** IQ7+ [5] VCOP 0.000 0.238 1.240 1.759 9.917
15 - 202245****** IQ7+M [5] VCOP 0.000 0.245 1.236 1.762 9.922
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.