Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.258 kW
09/17/2025 07:06 (1939 days) Production Consumption NET Usage
Now 0.085 kW 0.343 kW 0.258 kW
Today 0.007 kWh (0.001 kW) 2.838 kWh (0.399 kW) 2.831 kWh (0.398 kW)
  - This Week 60.893 kWh (18.469 kWh/day) 90.117 kWh (27.333 kWh/day) 29.224 kWh (8.864 kWh/day)
  - This Month 346.662 kWh (21.273 kWh/day) 394.674 kWh (24.219 kWh/day) 48.012 kWh (2.946 kWh/day)
  - This Year 4.854 MWh (18.720 kWh/day) 5.565 MWh (21.464 kWh/day) 0.711 MWh (2.744 kWh/day)
Yesterday 14.819 kWh (0.617 kW) 13.670 kWh (0.569 kW) -1.149 kWh (-0.048 kW)
Last 7 Days 144.530 kWh (20.648 kWh/day) 153.736 kWh (21.963 kWh/day) 9.206 kWh (1.315 kWh/day)
Last 30 Days 672.086 kWh (22.403 kWh/day) 697.605 kWh (23.253 kWh/day) 25.519 kWh (0.851 kWh/day)
Last One Year 6.262 MWh (17.156 kWh/day) 7.162 MWh (19.622 kWh/day) 0.900 MWh (2.466 kWh/day)
Lifetime Since PTO 34.305 MWh (17.689 kW/day) 37.517 MWh (19.346 kW/day) 3.212 MWh (1.657 kW/day)
Lifetime Since Install 34.339 MWh 38.097 MWh 3.759 MWh
Voltage/Current 252.3 V / 0.3 A 252.4 V / 1.4 A 252.4 V / 1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/07/2023 23:03 (9.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.586 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.182 0.428 0.995 6.727 0.000 kW
0.425 kWh
0.000 kW
2.548 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.175 0.415 0.945 6.365
03 - 202224****** IQ7+M [5] VC-- 0.000 0.181 0.431 0.979 6.597
04 - 202232****** IQ7+ [5] VC-- 0.000 0.182 0.435 0.983 6.630
05 - 202244****** IQ7+M [5] VC-- 0.000 0.175 0.419 0.949 6.426
06 - 202245****** IQ7+M [5] VCOP 0.000 0.177 0.420 0.970 6.622
front 07 - 202206****** IQ7+ [5] VC-- 0.000 0.247 0.508 0.900 6.823 0.000 kW
0.557 kWh
0.000 kW
2.785 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.247 0.530 1.052 7.573
09 - 202217****** IQ7+ [5] VCOP 0.000 0.247 0.599 1.141 8.002
10 - 202244****** IQ7+M [5] VCOP 0.000 0.244 0.580 1.122 7.915
11 - 202224****** IQ7+M [5] VC-- 0.000 0.246 0.568 1.081 7.794
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.073 0.280 0.608 3.954 0.000 kW
0.313 kWh
0.000 kW
1.253 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.078 0.310 0.658 4.350
14 - 202216****** IQ7+ [5] VCOP 0.000 0.082 0.332 0.692 4.555
15 - 202245****** IQ7+M [5] VCOP 0.000 0.079 0.330 0.689 4.531
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.406 20.328 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.59 V Current/Power -1.59 A (-83 W)
Remain Capacity/Energy 204.9 Ah (10.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 34.5 % State Of Health 98.9 %
Run Time 5d 8h 52m to empty Report Date 2023-11-07 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.