Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.377 kW
07/01/2025 08:12 (1861 days) Production Consumption NET Usage
Now 0.676 kW 0.299 kW -0.377 kW
Today 0.446 kWh (0.054 kW) 6.485 kWh (0.788 kW) 6.039 kWh (0.734 kW)
  - This Week 57.732 kWh (24.650 kWh/day) 74.167 kWh (31.668 kWh/day) 16.435 kWh (7.017 kWh/day)
  - This Month 0.446 kWh (1.301 kWh/day) 6.485 kWh (18.918 kWh/day) 6.039 kWh (17.617 kWh/day)
  - This Year 3.030 MWh (16.710 kWh/day) 3.134 MWh (17.281 kWh/day) 0.104 MWh (0.571 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.450 kW/day) 35.086 MWh (18.850 kW/day) 2.605 MWh (1.399 kW/day)
Lifetime Since Install 32.515 MWh 35.666 MWh 3.151 MWh
Voltage/Current 248.9 V / 2.7 A 248.8 V / 1.2 A 248.8 V / -1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/05/2023 23:42 (12.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.616 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.563 1.395 12.061 0.000 kW
1.511 kWh
0.000 kW
9.064 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.253 1.489 1.317 11.467
03 - 202224****** IQ7+M [5] VCOP 0.000 0.264 1.552 1.360 11.910
04 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.570 1.367 12.063
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.425 1.319 11.148
06 - 202245****** IQ7+M [5] VCOP 0.000 0.262 1.466 1.360 11.509
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.277 1.458 1.408 11.832 0.000 kW
1.520 kWh
0.000 kW
7.602 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.536 1.409 11.972
09 - 202217****** IQ7+ [5] VCOP 0.000 0.278 1.528 1.385 11.807
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.528 1.423 12.053
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.551 1.447 12.307
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.207 1.356 1.024 9.641 0.000 kW
1.396 kWh
0.000 kW
5.585 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.212 1.383 1.028 9.720
14 - 202216****** IQ7+ [5] VCOP 0.000 0.214 1.422 1.080 10.102
15 - 202245****** IQ7+M [5] VCOP 0.000 0.214 1.424 1.079 10.108
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.365 1.347 14.049 0.000 kW
1.365 kWh
0.000 kW
1.365 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.57 V Current/Power -6.12 A (-0.322 kW)
Remain Capacity/Energy 256.4 Ah (13.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 43.2 % State Of Health 98.9 %
Run Time 1d 17h 53m to empty Report Date 2023-09-05 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.