Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.105 kW
11/09/2025 12:36 (1992 days) Production Consumption NET Usage
Now 0.501 kW 0.396 kW -0.105 kW
Today 4.006 kWh (0.317 kW) 7.349 kWh (0.582 kW) 3.343 kWh (0.265 kW)
  - This Week 4.006 kWh (7.616 kWh/day) 7.349 kWh (13.972 kWh/day) 3.343 kWh (6.356 kWh/day)
  - This Month 114.039 kWh (13.375 kWh/day) 175.258 kWh (20.555 kWh/day) 61.219 kWh (7.180 kWh/day)
  - This Year 5.692 MWh (18.213 kWh/day) 6.508 MWh (20.823 kWh/day) 0.816 MWh (2.610 kWh/day)
Yesterday 15.394 kWh (0.641 kW) 24.543 kWh (1.022 kW) 9.149 kWh (0.381 kW)
Last 7 Days 93.095 kWh (13.299 kWh/day) 151.721 kWh (21.675 kWh/day) 58.626 kWh (8.375 kWh/day)
Last 30 Days 395.470 kWh (13.182 kWh/day) 463.753 kWh (15.459 kWh/day) 68.283 kWh (2.276 kWh/day)
Last One Year 6.171 MWh (16.908 kWh/day) 7.484 MWh (20.505 kWh/day) 1.313 MWh (3.597 kWh/day)
Lifetime Since PTO 35.143 MWh (17.637 kW/day) 38.460 MWh (19.302 kW/day) 3.318 MWh (1.665 kW/day)
Lifetime Since Install 35.177 MWh 39.040 MWh 3.864 MWh
Voltage/Current 250.3 V / 2.0 A 250.2 V / 1.6 A 250.3 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/23/2024 23:05 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.084 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.056 0.220 0.778 1.309 0.000 kW
0.209 kWh
0.000 kW
1.253 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.053 0.202 0.821 1.318
03 - 202224****** IQ7+M [5] VCOP 0.000 0.056 0.218 0.789 1.307
04 - 202232****** IQ7+ [5] VCOP 0.000 0.055 0.215 0.887 1.423
05 - 202244****** IQ7+M [5] VCOP 0.000 0.052 0.196 0.805 1.255
06 - 202245****** IQ7+M [5] VCOP 0.000 0.054 0.203 0.841 1.318
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.051 0.196 1.003 3.675 0.000 kW
0.199 kWh
0.000 kW
0.993 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.050 0.201 1.169 4.559
09 - 202217****** IQ7+ [5] VCOP 0.000 0.052 0.198 1.252 4.084
10 - 202244****** IQ7+M [5] VCOP 0.000 0.052 0.199 1.232 4.661
11 - 202224****** IQ7+M [5] VCOP 0.000 0.052 0.200 1.167 4.083
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.052 0.193 0.148 0.341 0.000 kW
0.209 kWh
0.000 kW
0.838 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.055 0.208 0.138 0.357
14 - 202216****** IQ7+ [5] VCOP 0.000 0.055 0.217 0.141 0.388
15 - 202245****** IQ7+M [5] VCOP 0.000 0.057 0.219 0.159 0.413
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.24 V Current/Power -0.72 A (-38 W)
Remain Capacity/Energy 411.1 Ah (21.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 69.3 % State Of Health 98.9 %
Run Time 23d 19h 2m to empty Report Date 2024-01-23 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.