Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.506 kW
12/05/2025 20:54 (2018 days) Production Consumption NET Usage
Now 0.000 kW 0.506 kW 0.506 kW
Today 7.358 kWh (0.352 kW) 10.591 kWh (0.507 kW) 3.233 kWh (0.155 kW)
  - This Week 45.198 kWh (7.699 kWh/day) 87.437 kWh (14.893 kWh/day) 42.239 kWh (7.195 kWh/day)
  - This Month 43.907 kWh (9.013 kWh/day) 69.429 kWh (14.252 kWh/day) 25.522 kWh (5.239 kWh/day)
  - This Year 5.913 MWh (17.449 kWh/day) 6.986 MWh (20.615 kWh/day) 1.073 MWh (3.166 kWh/day)
Yesterday 7.833 kWh (0.326 kW) 16.000 kWh (0.667 kW) 8.167 kWh (0.340 kW)
Last 7 Days 65.820 kWh (9.402 kWh/day) 136.993 kWh (19.569 kWh/day) 71.173 kWh (10.167 kWh/day)
Last 30 Days 269.265 kWh (8.975 kWh/day) 569.968 kWh (18.999 kWh/day) 300.703 kWh (10.023 kWh/day)
Last One Year 6.110 MWh (16.741 kWh/day) 7.492 MWh (20.525 kWh/day) 1.381 MWh (3.784 kWh/day)
Lifetime Since PTO 35.364 MWh (17.516 kW/day) 38.938 MWh (19.287 kW/day) 3.575 MWh (1.771 kW/day)
Lifetime Since Install 35.398 MWh 39.518 MWh 4.121 MWh
Voltage/Current 249.2 V / 0.0 A 249.3 V / 2.0 A 249.2 V / 2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/21/2024 23:43 (10.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.057 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.211 0.778 1.644 4.440 0.000 kW
0.753 kWh
0.000 kW
4.515 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.202 0.732 1.572 4.167
03 - 202224****** IQ7+M [0] ---- 0.000 0.209 0.771 1.624 4.291
04 - 202232****** IQ7+ [0] ---- 0.000 0.212 0.768 1.584 4.282
05 - 202244****** IQ7+M [0] ---- 0.000 0.201 0.720 1.554 5.132
06 - 202245****** IQ7+M [0] ---- 0.000 0.203 0.747 1.579 5.341
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.277 0.822 1.698 6.271 0.000 kW
0.830 kWh
0.000 kW
4.149 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.282 0.833 1.859 6.780
09 - 202217****** IQ7+ [0] ---- 0.000 0.278 0.829 1.913 10.826
10 - 202244****** IQ7+M [0] ---- 0.000 0.273 0.829 1.937 11.123
11 - 202224****** IQ7+M [0] ---- 0.000 0.277 0.836 1.929 10.756
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.102 0.549 0.822 2.148 0.000 kW
0.598 kWh
0.000 kW
2.392 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.108 0.592 0.957 2.292
14 - 202216****** IQ7+ [0] ---- 0.000 0.113 0.629 0.957 2.342
15 - 202245****** IQ7+M [0] ---- 0.000 0.112 0.622 0.981 2.351
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 1.682 13.561 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.