Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.255 kW
09/15/2025 13:40 (1937 days) Production Consumption NET Usage
Now 3.782 kW 0.527 kW -3.255 kW
Today 13.918 kWh (1.017 kW) 6.409 kWh (0.468 kW) -7.509 kWh (-0.548 kW)
  - This Week 37.072 kWh (23.599 kWh/day) 62.106 kWh (39.535 kWh/day) 25.034 kWh (15.936 kWh/day)
  - This Month 322.841 kWh (22.158 kWh/day) 366.663 kWh (25.165 kWh/day) 43.822 kWh (3.008 kWh/day)
  - This Year 4.830 MWh (18.753 kWh/day) 5.537 MWh (21.499 kWh/day) 0.707 MWh (2.746 kWh/day)
Yesterday 23.154 kWh (0.964 kW) 55.697 kWh (2.320 kW) 32.543 kWh (1.355 kW)
Last 7 Days 160.570 kWh (22.939 kWh/day) 141.441 kWh (20.206 kWh/day) -19.129 kWh (-2.733 kWh/day)
Last 30 Days 682.284 kWh (22.743 kWh/day) 742.377 kWh (24.746 kWh/day) 60.093 kWh (2.003 kWh/day)
Last One Year 6.272 MWh (17.184 kWh/day) 7.144 MWh (19.573 kWh/day) 0.872 MWh (2.389 kWh/day)
Lifetime Since PTO 34.281 MWh (17.693 kW/day) 37.489 MWh (19.349 kW/day) 3.208 MWh (1.656 kW/day)
Lifetime Since Install 34.315 MWh 38.069 MWh 3.754 MWh
Voltage/Current 249.6 V / 15.1 A 249.6 V / 2.1 A 249.6 V / -13.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/05/2023 23:07 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.045 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.109 0.506 0.536 4.086 0.000 kW
0.488 kWh
0.000 kW
2.930 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.103 0.474 0.505 3.870
03 - 202224****** IQ7+M [5] VCOP 0.000 0.107 0.501 0.532 4.059
04 - 202232****** IQ7+ [5] VCOP 0.000 0.108 0.500 0.532 4.078
05 - 202244****** IQ7+M [5] VCOP 0.000 0.102 0.466 0.495 3.869
06 - 202245****** IQ7+M [5] VCOP 0.000 0.104 0.483 0.515 3.944
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.113 0.485 0.519 4.082 0.000 kW
0.517 kWh
0.000 kW
2.585 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.122 0.523 0.561 4.544
09 - 202217****** IQ7+ [5] VCOP 0.000 0.120 0.535 0.578 4.845
10 - 202244****** IQ7+M [5] VCOP 0.000 0.118 0.528 0.564 4.766
11 - 202224****** IQ7+M [5] VCOP 0.000 0.117 0.513 0.552 4.517
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.075 0.353 0.361 1.995 0.000 kW
0.382 kWh
0.000 kW
1.530 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.079 0.373 0.382 2.252
14 - 202216****** IQ7+ [5] VCOP 0.000 0.084 0.401 0.407 2.384
15 - 202245****** IQ7+M [5] VCOP 0.000 0.085 0.403 0.405 2.358
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 10.862 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.26 V Current/Power -0.60 A (-31 W)
Remain Capacity/Energy 386.4 Ah (19.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.2 % State Of Health 98.9 %
Run Time 26d 20h 3m to empty Report Date 2023-12-05 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.