Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.011 kW
09/13/2025 12:10 (1935 days) Production Consumption NET Usage
Now 3.525 kW 0.514 kW -3.011 kW
Today 8.687 kWh (0.713 kW) 6.087 kWh (0.500 kW) -2.600 kWh (-0.214 kW)
  - This Week 135.081 kWh (20.758 kWh/day) 90.751 kWh (13.946 kWh/day) -44.330 kWh (-6.812 kWh/day)
  - This Month 272.009 kWh (21.748 kWh/day) 286.476 kWh (22.905 kWh/day) 14.467 kWh (1.157 kWh/day)
  - This Year 4.779 MWh (18.705 kWh/day) 5.457 MWh (21.358 kWh/day) 0.678 MWh (2.653 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.230 MWh (17.685 kW/day) 37.409 MWh (19.328 kW/day) 3.179 MWh (1.642 kW/day)
Lifetime Since Install 34.264 MWh 37.989 MWh 3.725 MWh
Voltage/Current 252.7 V / 13.9 A 252.7 V / 2.0 A 252.7 V / -11.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/06/2023 23:48 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.529 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.193 0.562 0.506 3.718 0.000 kW
0.545 kWh
0.000 kW
3.270 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.178 0.529 0.474 3.520
03 - 202224****** IQ7+M [5] VCOP 0.000 0.184 0.556 0.501 3.704
04 - 202232****** IQ7+ [5] VCOP 0.000 0.192 0.557 0.500 3.719
05 - 202244****** IQ7+M [5] VCOP 0.000 0.181 0.529 0.466 3.510
06 - 202245****** IQ7+M [5] VCOP 0.000 0.181 0.537 0.483 3.585
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.226 0.477 0.485 3.751 0.000 kW
0.572 kWh
0.000 kW
2.862 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.227 0.587 0.523 4.092
09 - 202217****** IQ7+ [5] VCOP 0.000 0.234 0.625 0.535 4.325
10 - 202244****** IQ7+M [5] VCOP 0.000 0.226 0.616 0.528 4.256
11 - 202224****** IQ7+M [5] VCOP 0.000 0.226 0.556 0.513 4.060
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.090 0.310 0.353 1.977 0.000 kW
0.349 kWh
0.000 kW
1.398 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.093 0.351 0.373 2.197
14 - 202216****** IQ7+ [5] VCOP 0.000 0.100 0.370 0.401 2.334
15 - 202245****** IQ7+M [5] VCOP 0.000 0.098 0.366 0.403 2.316
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 10.862 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.33 V Current/Power -0.90 A (-48 W)
Remain Capacity/Energy 425.1 Ah (21.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 71.7 % State Of Health 98.9 %
Run Time 19d 16h 20m to empty Report Date 2023-12-06 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.