Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.007 kW
01/07/2025 15:34 (1686 days) Production Consumption NET Usage
Now 0.409 kW 0.402 kW -0.007 kW
Today 14.537 kWh (0.933 kW) 11.482 kWh (0.737 kW) -3.055 kWh (-0.196 kW)
  - This Week 25.712 kWh (9.703 kWh/day) 55.036 kWh (20.769 kWh/day) 29.324 kWh (11.066 kWh/day)
  - This Month 58.831 kWh (8.848 kWh/day) 160.809 kWh (24.184 kWh/day) 101.978 kWh (15.337 kWh/day)
  - This Year 0.059 MWh (8.848 kWh/day) 0.161 MWh (24.184 kWh/day) 0.102 MWh (15.337 kWh/day)
Yesterday 2.184 kWh (0.091 kW) 22.828 kWh (0.951 kW) 20.644 kWh (0.860 kW)
Last 7 Days 55.203 kWh (7.886 kWh/day) 166.132 kWh (23.732 kWh/day) 110.929 kWh (15.846 kWh/day)
Last 30 Days 213.569 kWh (7.119 kWh/day) 632.199 kWh (21.073 kWh/day) 418.630 kWh (13.954 kWh/day)
Last One Year 6.703 MWh (18.364 kWh/day) 6.283 MWh (17.214 kWh/day) -0.420 MWh (-1.150 kWh/day)
Lifetime Since PTO 29.510 MWh (17.496 kW/day) 32.114 MWh (19.039 kW/day) 2.604 MWh (1.544 kW/day)
Lifetime Since Install 29.544 MWh 32.694 MWh 3.150 MWh
Voltage/Current 249.7 V / 1.6 A 249.6 V / 1.6 A 249.6 V / -0.0 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 04/08/2023 22:38 (12.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.151 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.299 1.839 0.790 9.234 0.000 kW
1.779 kWh
0.000 kW
10.672 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.294 1.758 0.741 8.845
03 - 202224101754 IQ7+M VCOP 0.000 0.297 1.839 0.782 9.219
04 - 202232127100 IQ7+ VCOP 0.000 0.299 1.867 0.780 9.279
05 - 202244171601 IQ7+M VCOP 0.000 0.294 1.662 0.715 8.582
06 - 202245013024 IQ7+M VCOP 0.000 0.297 1.707 0.743 8.742
front 07 - 202206091803 IQ7+ VCOP 0.000 0.299 1.682 0.695 8.875 0.000 kW
1.771 kWh
0.000 kW
8.855 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.299 1.793 0.711 9.196
09 - 202217001404 IQ7+ VCOP 0.000 0.300 1.791 0.712 9.130
10 - 202244165234 IQ7+M VCOP 0.000 0.299 1.785 0.715 9.262
11 - 202224104308 IQ7+M VCOP 0.000 0.299 1.803 0.718 9.337
back 12 - 202211186551 IQ7+ VCOP 0.000 0.241 1.638 0.756 7.377 0.000 kW
1.704 kWh
0.000 kW
6.816 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.251 1.694 0.800 7.585
14 - 202216155993 IQ7+ VCOP 0.000 0.254 1.743 0.841 7.985
15 - 202245015670 IQ7+M VCOP 0.000 0.252 1.740 0.841 7.973
wind 16 - 122214035120 IQ7PD ---- 0.000 0.234 1.808 1.809 13.464 0.000 kW
1.808 kWh
0.000 kW
1.808 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -1.29 A (-68 W)
Remain Capacity/Energy 524.4 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.4 % State Of Health 100.0 %
Run Time 16d 22h 30m to empty Report Date 2023-04-08 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack