Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.691 kW
07/01/2025 00:06 (1861 days) Production Consumption NET Usage
Now 0.000 kW 0.691 kW 0.691 kW
Today 0.000 kWh 0.288 kWh 0.288 kWh
  - This Week 57.286 kWh (28.576 kWh/day) 67.970 kWh (33.906 kWh/day) 10.684 kWh (5.330 kWh/day)
  - This Month 0.000 kWh 0.288 kWh 0.288 kWh
  - This Year 3.030 MWh (16.738 kWh/day) 3.128 MWh (17.279 kWh/day) 0.098 MWh (0.540 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.453 kW/day) 35.080 MWh (18.850 kW/day) 2.599 MWh (1.397 kW/day)
Lifetime Since Install 32.515 MWh 35.659 MWh 3.145 MWh
Voltage/Current 250.4 V / 0.0 A 250.5 V / 2.8 A 250.5 V / 2.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/08/2023 23:46 (18.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.493 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.202 0.923 0.259 8.553 0.000 kW
0.884 kWh
0.000 kW
5.306 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.220 0.871 0.243 8.148
03 - 202224****** IQ7+M [0] ---- 0.000 0.209 0.903 0.258 8.435
04 - 202232****** IQ7+ [0] ---- 0.000 0.203 0.904 0.255 8.498
05 - 202244****** IQ7+M [0] ---- 0.000 0.207 0.840 0.238 8.038
06 - 202245****** IQ7+M [0] ---- 0.000 0.209 0.864 0.248 8.193
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.263 0.760 0.238 8.443 0.000 kW
0.889 kWh
0.000 kW
4.445 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.264 0.885 0.238 9.074
09 - 202217****** IQ7+ [0] ---- 0.000 0.264 0.931 0.238 9.116
10 - 202244****** IQ7+M [0] ---- 0.000 0.255 0.934 0.238 9.104
11 - 202224****** IQ7+M [0] ---- 0.000 0.264 0.934 0.238 9.257
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.176 0.723 0.226 5.579 0.000 kW
0.758 kWh
0.000 kW
3.032 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.179 0.747 0.242 5.851
14 - 202216****** IQ7+ [0] ---- 0.000 0.171 0.781 0.257 6.104
15 - 202245****** IQ7+M [0] ---- 0.000 0.179 0.782 0.259 6.092
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 2.710 3.004 29.639 0.000 kW
2.710 kWh
0.000 kW
2.710 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.62 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 226.8 Ah (11.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 38.2 % State Of Health 98.9 %
Run Time 6d 7h 12m to empty Report Date 2023-10-08 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.