Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.826 kW
01/07/2025 16:25 (1686 days) Production Consumption NET Usage
Now 0.058 kW 2.884 kW 2.826 kW
Today 14.903 kWh (0.907 kW) 12.295 kWh (0.749 kW) -2.608 kWh (-0.159 kW)
  - This Week 26.078 kWh (9.712 kWh/day) 55.849 kWh (20.799 kWh/day) 29.771 kWh (11.087 kWh/day)
  - This Month 59.197 kWh (8.856 kWh/day) 161.622 kWh (24.178 kWh/day) 102.425 kWh (15.323 kWh/day)
  - This Year 0.059 MWh (8.856 kWh/day) 0.162 MWh (24.178 kWh/day) 0.102 MWh (15.323 kWh/day)
Yesterday 2.184 kWh (0.091 kW) 22.828 kWh (0.951 kW) 20.644 kWh (0.860 kW)
Last 7 Days 55.203 kWh (7.886 kWh/day) 166.132 kWh (23.732 kWh/day) 110.929 kWh (15.846 kWh/day)
Last 30 Days 213.569 kWh (7.119 kWh/day) 632.199 kWh (21.073 kWh/day) 418.630 kWh (13.954 kWh/day)
Last One Year 6.703 MWh (18.364 kWh/day) 6.283 MWh (17.214 kWh/day) -0.420 MWh (-1.150 kWh/day)
Lifetime Since PTO 29.510 MWh (17.495 kW/day) 32.114 MWh (19.039 kW/day) 2.604 MWh (1.544 kW/day)
Lifetime Since Install 29.544 MWh 32.694 MWh 3.150 MWh
Voltage/Current 246.4 V / 0.2 A 246.2 V / 11.7 A 246.3 V / 11.5 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 04/22/2023 22:43 (12.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.188 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.300 1.510 2.111 10.203 0.000 kW
1.478 kWh
0.000 kW
8.870 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.297 1.446 2.002 9.735
03 - 202224101754 IQ7+M VCOP 0.000 0.299 1.496 2.087 10.084
04 - 202232127100 IQ7+ VCOP 0.000 0.299 1.510 2.143 10.177
05 - 202244171601 IQ7+M VCOP 0.000 0.299 1.437 1.918 9.555
06 - 202245013024 IQ7+M VCOP 0.000 0.297 1.472 2.021 9.860
front 07 - 202206091803 IQ7+ VCOP 0.000 0.300 1.468 2.067 10.226 0.000 kW
1.480 kWh
0.000 kW
7.398 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.298 1.481 2.071 10.006
09 - 202217001404 IQ7+ VCOP 0.000 0.299 1.482 2.060 9.975
10 - 202244165234 IQ7+M VCOP 0.000 0.299 1.476 2.086 10.220
11 - 202224104308 IQ7+M VCOP 0.000 0.299 1.491 2.134 10.416
back 12 - 202211186551 IQ7+ VCOP 0.000 0.274 1.276 1.804 7.988 0.000 kW
1.335 kWh
0.000 kW
5.340 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.284 1.326 1.821 8.126
14 - 202216155993 IQ7+ VCOP 0.000 0.284 1.369 1.906 8.554
15 - 202245015670 IQ7+M VCOP 0.000 0.289 1.369 1.904 8.540
wind 16 - 122214035120 IQ7PD ---- 0.000 0.234 1.580 2.106 11.555 0.000 kW
1.580 kWh
0.000 kW
1.580 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.13 V Current/Power -7.96 A (-0.423 kW)
Remain Capacity/Energy 469.6 Ah (24.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 78.3 % State Of Health 100.0 %
Run Time 2d 10h 59m to empty Report Date 2023-04-22 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.17 V Cell (MIN/MAX) 3.317 V / 3.328 V (0.011 V)
Current/Power -2.18 A (-115 W) Runtime 2d 23h 55m to empty
Remain Capacity/Energy 156.5 Ah (8.0 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 78.3 % State Of Health 100.0 %
Temperature 22.5 °C Cycle 97
MOSFET CFET = ON, DFET = ON Reported 2023-04-22 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.318 V 3.317 V 3.319 V 3.322 V 3.320 V 3.320 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.323 V 3.325 V 3.325 V 3.327 V 3.325 V 3.328 V 3.328 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.