Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.287 kW
02/03/2026 21:46 (2078 days) Production Consumption NET Usage
Now 0.000 kW 0.287 kW 0.287 kW
Today 7.825 kWh (0.359 kW) 13.304 kWh (0.611 kW) 5.479 kWh (0.252 kW)
  - This Week 50.386 kWh (17.327 kWh/day) 85.450 kWh (29.385 kWh/day) 35.064 kWh (12.058 kWh/day)
  - This Month 50.386 kWh (17.327 kWh/day) 85.450 kWh (29.385 kWh/day) 35.064 kWh (12.058 kWh/day)
  - This Year 0.296 MWh (8.724 kWh/day) 0.669 MWh (19.719 kWh/day) 0.373 MWh (10.995 kWh/day)
Yesterday 20.377 kWh (0.849 kW) 15.260 kWh (0.636 kW) -5.117 kWh (-0.213 kW)
Last 7 Days 89.553 kWh (14.700 kWh/day) 139.763 kWh (22.942 kWh/day) 50.210 kWh (8.242 kWh/day)
Last 30 Days 251.143 kWh (8.632 kWh/day) 595.825 kWh (20.480 kWh/day) 344.682 kWh (11.847 kWh/day)
Last One Year 6.102 MWh (16.760 kWh/day) 7.545 MWh (20.723 kWh/day) 1.443 MWh (3.964 kWh/day)
Lifetime Since PTO 35.861 MWh (17.250 kW/day) 40.180 MWh (19.327 kW/day) 4.319 MWh (2.077 kW/day)
Lifetime Since Install 35.895 MWh 40.760 MWh 4.865 MWh
Voltage/Current 250.0 V / 0.0 A 250.1 V / 1.1 A 250.0 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/20/2024 23:40 (14.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.074 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.086 2.202 14.373 0.000 kW
1.970 kWh
0.000 kW
11.820 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.291 1.946 2.060 13.441
03 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.981 2.126 13.708
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.018 2.161 13.965
05 - 202244****** IQ7+M [0] ---- 0.000 0.291 1.789 1.925 12.211
06 - 202245****** IQ7+M [0] ---- 0.000 0.293 2.000 2.113 13.807
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.881 2.018 12.912 0.000 kW
1.862 kWh
0.000 kW
9.309 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.795 1.958 12.448
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.830 1.976 12.604
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.877 2.011 12.845
11 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.925 2.061 13.126
back 12 - 202211****** IQ7+ [0] V--- 0.000 0.252 1.926 1.991 13.731 0.000 kW
1.986 kWh
0.000 kW
7.944 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.260 1.930 2.007 13.870
14 - 202216****** IQ7+ [0] ---- 0.000 0.262 2.045 2.120 14.604
15 - 202245****** IQ7+M [0] ---- 0.000 0.264 2.044 2.121 14.599
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.92 V Current/Power -4.80 A (-0.254 kW)
Remain Capacity/Energy 363.1 Ah (18.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 61.2 % State Of Health 98.9 %
Run Time 3d 3h 38m to empty Report Date 2024-06-20 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack