Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.070 kW
03/16/2026 08:25 (2119 days) Production Consumption NET Usage
Now 0.062 kW 0.132 kW 0.070 kW
Today 0.029 kWh (0.003 kW) 3.514 kWh (0.416 kW) 3.485 kWh (0.413 kW)
  - This Week 11.918 kWh (8.818 kWh/day) 16.388 kWh (12.126 kWh/day) 4.470 kWh (3.307 kWh/day)
  - This Month 246.639 kWh (16.066 kWh/day) 220.415 kWh (14.358 kWh/day) -26.224 kWh (-1.708 kWh/day)
  - This Year 0.881 MWh (11.843 kWh/day) 1.320 MWh (17.757 kWh/day) 0.440 MWh (5.914 kWh/day)
Yesterday 11.889 kWh (0.495 kW) 12.874 kWh (0.537 kW) 0.985 kWh (0.041 kW)
Last 7 Days 142.020 kWh (20.289 kWh/day) 98.303 kWh (14.043 kWh/day) -43.717 kWh (-6.245 kWh/day)
Last 30 Days (02/14/2026) 410.004 kWh (13.667 kWh/day) 456.505 kWh (15.217 kWh/day) 46.501 kWh (1.550 kWh/day)
Last One Year 6.058 MWh (16.598 kWh/day) 7.841 MWh (21.483 kWh/day) 1.783 MWh (4.885 kWh/day)
Lifetime Since PTO 36.446 MWh (17.197 kW/day) 40.831 MWh (19.266 kW/day) 4.385 MWh (2.069 kW/day)
Lifetime Since Install 36.480 MWh 41.411 MWh 4.931 MWh
Voltage/Current 250.2 V / 0.2 A 250.3 V / 0.5 A 250.3 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/14/2024 23:04 (22.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.764 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.289 1.810 1.938 8.466 0.000 kW
1.731 kWh
0.000 kW
10.383 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.696 1.823 7.940
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.769 1.890 8.268
04 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.802 1.932 8.405
05 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.593 1.712 7.484
06 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.713 1.833 8.006
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.286 1.691 1.815 7.865 0.000 kW
1.699 kWh
0.000 kW
8.495 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.694 1.819 7.839
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.674 1.807 7.816
10 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.699 1.834 7.926
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.737 1.860 8.070
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.245 1.601 1.767 7.645 0.000 kW
1.659 kWh
0.000 kW
6.637 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.252 1.642 1.773 7.738
14 - 202216****** IQ7+ [5] VCOP 0.000 0.257 1.700 1.866 8.183
15 - 202245****** IQ7+M [5] VCOP 0.000 0.259 1.694 1.854 8.142
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.624 kWh
0.000 kW
5.249 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.246 5.249 5.518 18.007
Panel Layout Each Group Production

Battery History
Voltage 51.63 V Current/Power -3.90 A (-0.201 kW)
Remain Capacity/Energy 82.8 Ah (4.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 14.0 % State Of Health 98.9 %
Run Time 21h 14m to empty Report Date 2024-08-14 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.