Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.851 kW
05/30/2026 11:44 (2194 days) Production Consumption NET Usage
Now 2.077 kW 0.226 kW -1.851 kW
Today 11.294 kWh (0.960 kW) 5.663 kWh (0.481 kW) -5.631 kWh (-0.479 kW)
  - This Week 169.909 kWh (26.182 kWh/day) 146.377 kWh (22.556 kWh/day) -23.532 kWh (-3.626 kWh/day)
  - This Month 731.904 kWh (24.819 kWh/day) 502.546 kWh (17.041 kWh/day) -229.358 kWh (-7.778 kWh/day)
  - This Year 2.685 MWh (17.961 kWh/day) 2.562 MWh (17.140 kWh/day) -0.123 MWh (-0.821 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 172.260 kWh (24.609 kWh/day) 151.781 kWh (21.683 kWh/day) -20.479 kWh (-2.926 kWh/day)
Last 30 Days (04/30/2026) 739.190 kWh (24.640 kWh/day) 507.866 kWh (16.929 kWh/day) -231.324 kWh (-7.711 kWh/day)
Last One Year 6.433 MWh (17.624 kWh/day) 7.836 MWh (21.469 kWh/day) 1.403 MWh (3.845 kWh/day)
Lifetime Since PTO 38.251 MWh (17.430 kW/day) 42.073 MWh (19.172 kW/day) 3.822 MWh (1.742 kW/day)
Lifetime Since Install 38.285 MWh 42.653 MWh 4.368 MWh
Voltage/Current 249.3 V / 8.3 A 249.3 V / 0.9 A 249.3 V / -7.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/29/2024 23:00 (18.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.174 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.229 0.641 1.233 9.038 0.000 kW
0.618 kWh
0.000 kW
3.708 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.196 0.602 1.159 8.582
03 - 202224****** IQ7+M [5] VCOP 0.000 0.199 0.624 1.183 8.799
04 - 202232****** IQ7+ [5] VCOP 0.000 0.229 0.625 1.179 8.763
05 - 202244****** IQ7+M [5] VCOP 0.000 0.194 0.596 1.160 8.623
06 - 202245****** IQ7+M [5] VCOP 0.000 0.202 0.619 1.202 8.786
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.238 0.584 1.387 9.499 0.000 kW
0.640 kWh
0.000 kW
3.198 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.220 0.634 1.453 10.396
09 - 202217****** IQ7+ [5] VCOP 0.000 0.217 0.667 1.490 10.934
10 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.665 1.471 10.775
11 - 202224****** IQ7+M [5] VCOP 0.000 0.241 0.648 1.466 10.722
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.138 0.450 0.596 4.509 0.000 kW
0.487 kWh
0.000 kW
1.948 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.147 0.481 0.677 5.085
14 - 202216****** IQ7+ [5] VCOP 0.000 0.150 0.511 0.706 5.307
15 - 202245****** IQ7+M [5] VCOP 0.000 0.149 0.506 0.699 5.245
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.160 kWh
0.000 kW
4.320 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.230 4.320 5.497 9.104
Panel Layout Each Group Production

Charger History
Voltage PV 0.64 V Voltage Charge 52.97 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 25.8 °C / 23.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-10-29 23:58
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.