Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.308 kW
07/01/2026 17:51 (2226 days) Production Consumption NET Usage
Now 1.558 kW 2.866 kW 1.308 kW
Today 24.274 kWh (1.358 kW) 27.506 kWh (1.538 kW) 3.232 kWh (0.181 kW)
  - This Week 105.875 kWh (28.276 kWh/day) 101.646 kWh (27.146 kWh/day) -4.229 kWh (-1.129 kWh/day)
  - This Month 24.274 kWh (32.584 kWh/day) 27.506 kWh (36.922 kWh/day) 3.232 kWh (4.338 kWh/day)
  - This Year 3.634 MWh (19.996 kWh/day) 3.314 MWh (18.236 kWh/day) -0.320 MWh (-1.760 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 165.357 kWh (23.622 kWh/day) 166.201 kWh (23.743 kWh/day) 0.844 kWh (0.121 kWh/day)
Last 30 Days (06/01/2026) 866.195 kWh (28.873 kWh/day) 738.541 kWh (24.618 kWh/day) -127.654 kWh (-4.255 kWh/day)
Last One Year 6.698 MWh (18.351 kWh/day) 7.722 MWh (21.156 kWh/day) 1.024 MWh (2.804 kWh/day)
Lifetime Since PTO 39.200 MWh (17.604 kW/day) 42.825 MWh (19.232 kW/day) 3.625 MWh (1.628 kW/day)
Lifetime Since Install 39.234 MWh 43.405 MWh 4.171 MWh
Voltage/Current 246.5 V / 6.3 A 246.4 V / 11.6 A 246.4 V / 5.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/04/2024 23:23 (8.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.715 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.138 0.504 0.706 5.070 0.000 kW
0.486 kWh
0.000 kW
2.913 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.132 0.471 0.664 4.831
03 - 202224****** IQ7+M [5] VCOP 0.000 0.136 0.498 0.691 5.028
04 - 202232****** IQ7+ [5] VCOP 0.000 0.136 0.499 0.695 5.062
05 - 202244****** IQ7+M [5] VCOP 0.000 0.131 0.462 0.664 4.854
06 - 202245****** IQ7+M [5] VCOP 0.000 0.132 0.480 0.681 4.943
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.148 0.363 0.703 5.337 0.000 kW
0.457 kWh
0.000 kW
2.284 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.150 0.455 0.816 6.004
09 - 202217****** IQ7+ [5] VCOP 0.000 0.150 0.526 0.813 6.282
10 - 202244****** IQ7+M [5] VCOP 0.000 0.152 0.511 0.812 6.226
11 - 202224****** IQ7+M [5] VCOP 0.000 0.155 0.430 0.811 5.981
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.086 0.360 0.381 2.097 0.000 kW
0.379 kWh
0.000 kW
1.518 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.091 0.376 0.419 2.456
14 - 202216****** IQ7+ [5] VCOP 0.000 0.093 0.395 0.436 2.698
15 - 202245****** IQ7+M [5] VCOP 0.000 0.094 0.387 0.432 2.673
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 4.712 15.717
Panel Layout Each Group Production

Charger History
Voltage PV 2.10 V Voltage Charge 52.09 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.8 °C / 24.5 °C Flags 00/00/00 Energy Today 2.948 kWh @ 2024-12-04 23:55
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.