Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.365 kW
07/13/2025 06:52 (1873 days) Production Consumption NET Usage
Now 0.052 kW 0.417 kW 0.365 kW
Today 0.007 kWh (0.001 kW) 5.039 kWh (0.730 kW) 5.032 kWh (0.729 kW)
  - This Week 0.007 kWh (0.024 kWh/day) 5.039 kWh (17.516 kWh/day) 5.032 kWh (17.491 kWh/day)
  - This Month 297.085 kWh (24.178 kWh/day) 501.897 kWh (40.846 kWh/day) 204.812 kWh (16.668 kWh/day)
  - This Year 3.327 MWh (17.212 kWh/day) 3.629 MWh (18.776 kWh/day) 0.302 MWh (1.564 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.778 MWh (17.497 kW/day) 35.581 MWh (18.994 kW/day) 2.803 MWh (1.497 kW/day)
Lifetime Since Install 32.812 MWh 36.161 MWh 3.349 MWh
Voltage/Current 250.2 V / 0.2 A 250.2 V / 1.7 A 250.2 V / 1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/11/2024 23:06 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.765 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.225 0.788 0.374 2.790 0.000 kW
0.775 kWh
0.000 kW
4.653 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.215 0.748 0.350 2.588
03 - 202224****** IQ7+M [5] VC-- 0.000 0.217 0.791 0.371 2.699
04 - 202232****** IQ7+ [5] VC-- 0.000 0.222 0.802 0.369 2.730
05 - 202244****** IQ7+M [5] VC-- 0.000 0.209 0.757 0.352 2.737
06 - 202245****** IQ7+M [5] VCOP 0.000 0.214 0.766 0.360 2.799
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 0.780 0.234 3.289 0.000 kW
0.925 kWh
0.000 kW
4.623 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.283 0.925 0.370 3.761
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 1.009 0.399 4.263
10 - 202244****** IQ7+M [5] VCOP 0.000 0.285 0.993 0.395 4.239
11 - 202224****** IQ7+M [5] VC-- 0.000 0.285 0.917 0.342 4.031
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.118 0.341 0.248 1.339 0.000 kW
0.372 kWh
0.000 kW
1.489 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.126 0.374 0.266 1.440
14 - 202216****** IQ7+ [5] VCOP 0.000 0.131 0.389 0.280 1.495
15 - 202245****** IQ7+M [5] VCOP 0.000 0.130 0.384 0.278 1.504
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.69 V Current/Power -1.05 A (-55 W)
Remain Capacity/Energy 293.7 Ah (15.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 49.5 % State Of Health 98.9 %
Run Time 11d 15h 42m to empty Report Date 2024-01-11 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack