Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.352 kW
06/22/2026 09:55 (2217 days) Production Consumption NET Usage
Now 0.488 kW 0.136 kW -0.352 kW
Today 1.281 kWh (0.129 kW) 1.451 kWh (0.146 kW) 0.170 kWh (0.017 kW)
  - This Week 29.565 kWh (20.907 kWh/day) 17.966 kWh (12.705 kWh/day) -11.599 kWh (-8.202 kWh/day)
  - This Month 689.211 kWh (32.183 kWh/day) 504.822 kWh (23.573 kWh/day) -184.389 kWh (-8.610 kWh/day)
  - This Year 3.424 MWh (19.857 kWh/day) 3.075 MWh (17.834 kWh/day) -0.349 MWh (-2.023 kWh/day)
Yesterday 28.284 kWh (1.180 kW) 16.515 kWh (0.689 kW) -11.769 kWh (-0.491 kW)
Last 7 Days 201.202 kWh (28.743 kWh/day) 94.276 kWh (13.468 kWh/day) -106.926 kWh (-15.275 kWh/day)
Last 30 Days (05/23/2026) 912.280 kWh (30.409 kWh/day) 665.351 kWh (22.178 kWh/day) -246.929 kWh (-8.231 kWh/day)
Last One Year 6.716 MWh (18.401 kWh/day) 7.834 MWh (21.464 kWh/day) 1.118 MWh (3.064 kWh/day)
Lifetime Since PTO 38.989 MWh (17.583 kW/day) 42.586 MWh (19.205 kW/day) 3.596 MWh (1.622 kW/day)
Lifetime Since Install 39.023 MWh 43.166 MWh 4.142 MWh
Voltage/Current 246.8 V / 2.0 A 246.6 V / 0.6 A 246.7 V / -1.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/01/2025 23:00 (10.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.074 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.457 1.712 9.215 0.000 kW
1.405 kWh
0.000 kW
8.430 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.266 1.394 1.628 8.749
03 - 202224****** IQ7+M [5] VCOP 0.000 0.271 1.335 1.675 9.048
04 - 202232****** IQ7+ [5] VCOP 0.000 0.278 1.444 1.685 9.081
05 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.384 1.628 8.706
06 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.415 1.661 8.890
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.447 1.640 8.792 0.000 kW
1.552 kWh
0.000 kW
7.761 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.559 1.793 9.584
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.570 1.867 9.994
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.588 1.857 9.942
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.598 1.861 9.912
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.193 0.931 1.022 5.966 0.000 kW
0.971 kWh
0.000 kW
3.883 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.195 0.969 1.091 6.332
14 - 202216****** IQ7+ [5] VCOP 0.000 0.194 0.996 1.127 6.531
15 - 202245****** IQ7+M [5] VCOP 0.000 0.197 0.988 1.117 6.495
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 202300****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.91 V Voltage Charge 52.69 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.1 °C / 24.8 °C Flags 00/00/00 Energy Today 8.725 kWh @ 2025-03-01 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.95 V Current/Power -6.33 A (-0.335 kW)
Remain Capacity/Energy 382.8 Ah (19.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 64.5 % State Of Health 98.9 %
Run Time 2d 12h 28m to empty Report Date 2025-03-01 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.