Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.192 kW
12/11/2025 23:16 (2025 days) Production Consumption NET Usage
Now 0.000 kW 0.192 kW 0.192 kW
Today 12.082 kWh (0.375 kW) 15.015 kWh (0.466 kW) 2.933 kWh (0.091 kW)
  - This Week 49.566 kWh (9.972 kWh/day) 97.803 kWh (19.677 kWh/day) 48.237 kWh (9.705 kWh/day)
  - This Month 102.388 kWh (9.333 kWh/day) 187.336 kWh (17.076 kWh/day) 84.948 kWh (7.743 kWh/day)
  - This Year 5.971 MWh (17.310 kWh/day) 7.104 MWh (20.592 kWh/day) 1.132 MWh (3.282 kWh/day)
Yesterday 6.826 kWh (0.453 kW) 4.828 kWh (0.321 kW) -1.998 kWh (-0.133 kW)
Last 7 Days 61.590 kWh (9.293 kWh/day) 129.483 kWh (19.538 kWh/day) 67.893 kWh (10.244 kWh/day)
Last 30 Days 262.098 kWh (8.846 kWh/day) 556.415 kWh (18.780 kWh/day) 294.317 kWh (9.934 kWh/day)
Last One Year 6.114 MWh (16.767 kWh/day) 7.528 MWh (20.645 kWh/day) 1.414 MWh (3.877 kWh/day)
Lifetime Since PTO 35.422 MWh (17.492 kW/day) 39.056 MWh (19.287 kW/day) 3.634 MWh (1.795 kW/day)
Lifetime Since Install 35.456 MWh 39.636 MWh 4.180 MWh
Voltage/Current 250.5 V / 0.0 A 250.4 V / 0.8 A 250.4 V / 0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/01/2024 23:54 (23.9 hours) Number of Devices 17 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 19.889 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.260 1.039 0.576 9.125 0.000 kW
1.008 kWh
0.000 kW
6.049 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.248 0.986 0.545 8.640
03 - 202224****** IQ7+M [0] ---- 0.000 0.254 1.021 0.571 9.010
04 - 202232****** IQ7+ [0] ---- 0.000 0.256 1.018 0.572 9.135
05 - 202244****** IQ7+M [0] ---- 0.000 0.250 0.979 0.535 8.303
06 - 202245****** IQ7+M [0] ---- 0.000 0.247 1.007 0.555 8.658
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.289 1.107 0.530 8.616 0.000 kW
1.083 kWh
0.000 kW
5.414 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.060 0.533 8.770
09 - 202217****** IQ7+ [0] ---- 0.000 0.285 1.031 0.531 8.683
10 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.096 0.533 8.764
11 - 202224****** IQ7+M [0] ---- 0.000 0.289 1.120 0.536 8.904
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.176 0.697 0.505 7.745 0.000 kW
0.733 kWh
0.000 kW
2.932 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.191 0.705 0.533 7.993
14 - 202216****** IQ7+ [0] ---- 0.000 0.195 0.767 0.562 8.325
15 - 202245****** IQ7+M [0] ---- 0.000 0.191 0.764 0.562 8.309
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.747 kWh
0.229 kW
5.494 kWh
17 - 122214****** IQ7PD [5] VCOP 0.229 0.230 5.494 5.493 6.073
Panel Layout Each Group Production

Charger History
Voltage PV 0.42 V Voltage Charge 52.11 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.6 °C / 29.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-09-01 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.38 V Current/Power -6.29 A (-0.329 kW)
Remain Capacity/Energy 232.7 Ah (11.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 39.2 % State Of Health 98.9 %
Run Time 1d 12h 59m to empty Report Date 2024-09-01 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.