Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.002 kW
03/13/2026 22:30 (2116 days) Production Consumption NET Usage
Now 0.317 kW 0.315 kW -0.002 kW
Today 20.077 kWh (0.891 kW) 12.813 kWh (0.569 kW) -7.264 kWh (-0.322 kW)
  - This Week 106.360 kWh (17.912 kWh/day) 82.108 kWh (13.828 kWh/day) -24.252 kWh (-4.084 kWh/day)
  - This Month 200.068 kWh (15.464 kWh/day) 188.407 kWh (14.563 kWh/day) -11.661 kWh (-0.901 kWh/day)
  - This Year 0.834 MWh (11.593 kWh/day) 1.288 MWh (17.908 kWh/day) 0.454 MWh (6.314 kWh/day)
Yesterday 10.309 kWh (0.430 kW) 12.404 kWh (0.517 kW) 2.095 kWh (0.087 kW)
Last 7 Days 112.409 kWh (16.058 kWh/day) 98.107 kWh (14.015 kWh/day) -14.302 kWh (-2.043 kWh/day)
Last 30 Days (02/11/2026) 382.023 kWh (12.734 kWh/day) 489.346 kWh (16.312 kWh/day) 107.323 kWh (3.577 kWh/day)
Last One Year 6.020 MWh (16.493 kWh/day) 7.821 MWh (21.428 kWh/day) 1.801 MWh (4.935 kWh/day)
Lifetime Since PTO 36.400 MWh (17.194 kW/day) 40.799 MWh (19.273 kW/day) 4.399 MWh (2.078 kW/day)
Lifetime Since Install 36.434 MWh 41.379 MWh 4.945 MWh
Voltage/Current 250.6 V / 1.3 A 250.8 V / 1.3 A 250.7 V / -0.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/01/2025 23:55 (9.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.638 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.142 0.275 0.815 4.251 0.000 kW
0.263 kWh
0.000 kW
1.579 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.126 0.257 0.782 4.062
03 - 202224****** IQ7+M [0] ---- 0.000 0.139 0.272 0.817 4.193
04 - 202232****** IQ7+ [0] ---- 0.000 0.126 0.270 0.830 4.536
05 - 202244****** IQ7+M [0] ---- 0.000 0.126 0.246 0.785 4.358
06 - 202245****** IQ7+M [0] ---- 0.000 0.144 0.259 0.789 4.388
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.063 0.179 0.780 5.007 0.000 kW
0.237 kWh
0.000 kW
1.183 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.141 0.249 0.914 5.485
09 - 202217****** IQ7+ [0] ---- 0.000 0.144 0.277 1.000 5.727
10 - 202244****** IQ7+M [0] ---- 0.000 0.139 0.266 0.976 5.637
11 - 202224****** IQ7+M [0] ---- 0.000 0.139 0.212 0.891 5.436
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.082 0.207 0.354 1.718 0.000 kW
0.219 kWh
0.000 kW
0.876 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.084 0.217 0.390 1.489
14 - 202216****** IQ7+ [0] ---- 0.000 0.085 0.228 0.404 1.532
15 - 202245****** IQ7+M [0] ---- 0.000 0.079 0.223 0.397 1.705
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.56 V Voltage Charge 52.71 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.0 °C / 25.8 °C Flags 00/00/00 Energy Today 1.471 kWh @ 2025-01-01 23:57
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.