Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.890 kW
06/30/2025 16:53 (1860 days) Production Consumption NET Usage
Now 2.712 kW 1.822 kW -0.890 kW
Today 24.779 kWh (1.465 kW) 17.654 kWh (1.044 kW) -7.125 kWh (-0.421 kW)
  - This Week 54.737 kWh (32.120 kWh/day) 54.673 kWh (32.082 kWh/day) -0.064 kWh (-0.038 kWh/day)
  - This Month 626.026 kWh (21.075 kWh/day) 760.307 kWh (25.596 kWh/day) 134.281 kWh (4.521 kWh/day)
  - This Year 3.027 MWh (16.752 kWh/day) 3.114 MWh (17.234 kWh/day) 0.087 MWh (0.482 kWh/day)
Yesterday 29.958 kWh (1.249 kW) 37.019 kWh (1.543 kW) 7.061 kWh (0.294 kW)
Last 7 Days 164.939 kWh (23.565 kWh/day) 274.127 kWh (39.165 kWh/day) 109.188 kWh (15.600 kWh/day)
Last 30 Days 617.926 kWh (20.598 kWh/day) 775.650 kWh (25.855 kWh/day) 157.724 kWh (5.257 kWh/day)
Last One Year 6.346 MWh (17.387 kWh/day) 6.392 MWh (17.513 kWh/day) 0.046 MWh (0.126 kWh/day)
Lifetime Since PTO 32.478 MWh (17.455 kW/day) 35.066 MWh (18.846 kW/day) 2.588 MWh (1.391 kW/day)
Lifetime Since Install 32.512 MWh 35.646 MWh 3.134 MWh
Voltage/Current 247.8 V / 10.9 A 247.8 V / 7.4 A 247.8 V / -3.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/04/2024 23:57 (23.9 hours) Number of Devices 16 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 21.060 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.254 1.096 1.589 11.454 0.000 kW
1.029 kWh
0.000 kW
6.171 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.254 1.013 1.524 10.888
03 - 202224****** IQ7+M [5] VCOP 0.000 0.257 1.059 1.576 11.289
04 - 202232****** IQ7+ [5] VCOP 0.000 0.262 1.087 1.583 11.439
05 - 202244****** IQ7+M [5] VCOP 0.000 0.252 0.894 1.513 10.537
06 - 202245****** IQ7+M [5] VCOP 0.000 0.263 1.023 1.547 11.025
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.253 0.901 1.575 11.003 0.000 kW
0.922 kWh
0.000 kW
4.609 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.263 0.931 1.579 10.894
09 - 202217****** IQ7+ [5] VCOP 0.000 0.263 0.922 1.574 10.844
10 - 202244****** IQ7+M [5] VCOP 0.000 0.240 0.920 1.571 10.957
11 - 202224****** IQ7+M [5] VCOP 0.000 0.267 0.934 1.588 11.186
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.254 1.138 1.318 9.748 0.000 kW
1.197 kWh
0.000 kW
4.787 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.251 1.188 1.357 9.927
14 - 202216****** IQ7+ [5] VCOP 0.000 0.251 1.230 1.421 10.444
15 - 202245****** IQ7+M [5] VCOP 0.000 0.261 1.231 1.417 10.428
wind 16 - 122214****** IQ7PD [0] ---- 0.230 0.231 5.493 5.512 16.432 0.230 kW
5.493 kWh
0.230 kW
5.493 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.05 V Current/Power -6.30 A (-0.334 kW)
Remain Capacity/Energy 432.6 Ah (22.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 72.9 % State Of Health 98.9 %
Run Time 2d 20h 40m to empty Report Date 2024-05-04 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.