Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.388 kW
07/01/2025 04:32 (1861 days) Production Consumption NET Usage
Now 0.000 kW 0.388 kW 0.388 kW
Today 0.000 kWh (0.000 kW) 3.636 kWh (0.797 kW) 3.636 kWh (0.797 kW)
  - This Week 57.286 kWh (26.167 kWh/day) 71.318 kWh (32.576 kWh/day) 14.032 kWh (6.409 kWh/day)
  - This Month 0.000 kWh (0.000 kWh/day) 3.636 kWh (19.132 kWh/day) 3.636 kWh (19.132 kWh/day)
  - This Year 3.030 MWh (16.721 kWh/day) 3.131 MWh (17.280 kWh/day) 0.101 MWh (0.558 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.452 kW/day) 35.083 MWh (18.850 kW/day) 2.602 MWh (1.398 kW/day)
Lifetime Since Install 32.515 MWh 35.663 MWh 3.148 MWh
Voltage/Current 251.7 V / 0.0 A 251.7 V / 1.5 A 251.7 V / 1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/26/2024 23:23 (14.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.925 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.134 2.065 14.348 0.000 kW
2.054 kWh
0.000 kW
12.322 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.292 2.024 1.928 13.456
03 - 202224****** IQ7+M [0] ---- 0.000 0.295 2.087 1.972 13.825
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 2.125 2.027 14.128
05 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.887 1.742 12.507
06 - 202245****** IQ7+M [0] ---- 0.000 0.293 2.066 1.977 13.772
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 2.018 1.875 13.270 0.000 kW
1.999 kWh
0.000 kW
9.993 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.963 1.825 12.914
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.981 1.847 12.973
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.997 1.857 13.162
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 2.035 1.888 13.477
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.272 1.834 1.992 12.915 0.000 kW
1.902 kWh
0.000 kW
7.609 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.279 1.845 2.024 12.982
14 - 202216****** IQ7+ [0] ---- 0.000 0.279 1.963 2.119 13.706
15 - 202245****** IQ7+M [0] ---- 0.000 0.271 1.966 2.120 13.693
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.68 V Current/Power -7.20 A (-0.379 kW)
Remain Capacity/Energy 339.3 Ah (17.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.2 % State Of Health 98.9 %
Run Time 1d 23h 7m to empty Report Date 2024-05-26 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.