Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.724 kW
06/16/2026 07:27 (2211 days) Production Consumption NET Usage
Now 0.673 kW -0.051 kW -0.724 kW
Today 0.704 kWh (0.094 kW) 0.382 kWh (0.051 kW) -0.322 kWh (-0.043 kW)
  - This Week 59.044 kWh (25.550 kWh/day) 36.987 kWh (16.005 kWh/day) -22.057 kWh (-9.545 kWh/day)
  - This Month 517.396 kWh (33.790 kWh/day) 419.868 kWh (27.421 kWh/day) -97.528 kWh (-6.369 kWh/day)
  - This Year 3.252 MWh (19.553 kWh/day) 2.990 MWh (17.977 kWh/day) -0.262 MWh (-1.575 kWh/day)
Yesterday 32.903 kWh (1.371 kW) 12.207 kWh (0.509 kW) -20.696 kWh (-0.862 kW)
Last 7 Days 211.084 kWh (30.155 kWh/day) 215.209 kWh (30.744 kWh/day) 4.125 kWh (0.589 kWh/day)
Last 30 Days (05/17/2026) 896.439 kWh (29.881 kWh/day) 729.646 kWh (24.322 kWh/day) -166.793 kWh (-5.560 kWh/day)
Last One Year 6.650 MWh (18.220 kWh/day) 7.922 MWh (21.705 kWh/day) 1.272 MWh (3.485 kWh/day)
Lifetime Since PTO 38.817 MWh (17.554 kW/day) 42.501 MWh (19.220 kW/day) 3.683 MWh (1.666 kW/day)
Lifetime Since Install 38.851 MWh 43.081 MWh 4.229 MWh
Voltage/Current 250.0 V / 2.7 A 250.1 V / -0.2 A 250.0 V / -2.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/26/2025 23:34 (14.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.766 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.292 2.075 1.326 9.031 0.000 kW
1.962 kWh
0.000 kW
11.774 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.955 1.215 8.510
03 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.965 1.227 8.669
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 2.004 1.254 8.786
05 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.759 1.155 7.956
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 2.017 1.257 8.763
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.870 1.201 8.344 0.000 kW
1.869 kWh
0.000 kW
9.347 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.846 1.172 8.011
09 - 202217****** IQ7+ [5] VCOP 0.000 0.292 1.850 1.196 8.167
10 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.880 1.211 8.363
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.901 1.211 8.388
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.288 2.133 1.444 8.622 0.000 kW
2.161 kWh
0.000 kW
8.645 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.288 2.121 1.470 8.618
14 - 202216****** IQ7+ [5] VCOP 0.000 0.289 2.194 1.520 9.179
15 - 202245****** IQ7+M [5] VCOP 0.000 0.290 2.197 1.520 9.198
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.62 V Voltage Charge 52.34 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.0 °C / 25.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-05-26 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.57 V Current/Power -6.38 A (-0.335 kW)
Remain Capacity/Energy 325.1 Ah (16.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 54.8 % State Of Health 98.9 %
Run Time 2d 2h 56m to empty Report Date 2025-05-26 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.