Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.428 kW
11/08/2025 18:47 (1991 days) Production Consumption NET Usage
Now 0.000 kW 0.428 kW 0.428 kW
Today 15.394 kWh (0.818 kW) 20.616 kWh (1.096 kW) 5.222 kWh (0.278 kW)
  - This Week 93.095 kWh (13.724 kWh/day) 147.794 kWh (21.788 kWh/day) 54.699 kWh (8.064 kWh/day)
  - This Month 110.033 kWh (14.136 kWh/day) 163.982 kWh (21.068 kWh/day) 53.949 kWh (6.931 kWh/day)
  - This Year 5.688 MWh (18.243 kWh/day) 6.496 MWh (20.836 kWh/day) 0.808 MWh (2.593 kWh/day)
Yesterday 12.014 kWh (0.501 kW) 17.431 kWh (0.727 kW) 5.417 kWh (0.226 kW)
Last 7 Days 94.639 kWh (13.521 kWh/day) 143.366 kWh (20.482 kWh/day) 48.727 kWh (6.961 kWh/day)
Last 30 Days 404.420 kWh (13.481 kWh/day) 451.988 kWh (15.066 kWh/day) 47.568 kWh (1.586 kWh/day)
Last One Year 6.173 MWh (16.912 kWh/day) 7.473 MWh (20.473 kWh/day) 1.300 MWh (3.561 kWh/day)
Lifetime Since PTO 35.139 MWh (17.642 kW/day) 38.449 MWh (19.303 kW/day) 3.310 MWh (1.662 kW/day)
Lifetime Since Install 35.173 MWh 39.029 MWh 3.856 MWh
Voltage/Current 250.6 V / 0.0 A 250.8 V / 1.7 A 250.7 V / 1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/09/2024 23:53 (9.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.194 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.203 0.967 1.117 7.389 0.000 kW
0.934 kWh
0.000 kW
5.605 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.193 0.911 1.061 7.018
03 - 202224****** IQ7+M [0] ---- 0.000 0.199 0.957 1.091 7.232
04 - 202232****** IQ7+ [0] ---- 0.000 0.199 0.889 1.091 7.265
05 - 202244****** IQ7+M [0] ---- 0.000 0.193 0.930 1.069 7.072
06 - 202245****** IQ7+M [0] ---- 0.000 0.195 0.951 1.092 7.227
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.257 1.118 1.147 7.885 0.000 kW
1.232 kWh
0.000 kW
6.162 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.257 1.196 1.301 8.782
09 - 202217****** IQ7+ [0] ---- 0.000 0.257 1.324 1.462 9.460
10 - 202244****** IQ7+M [0] ---- 0.000 0.254 1.287 1.427 9.304
11 - 202224****** IQ7+M [0] ---- 0.000 0.258 1.238 1.363 9.102
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.099 0.447 0.456 3.351 0.000 kW
0.512 kWh
0.000 kW
2.047 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.105 0.513 0.537 3.872
14 - 202216****** IQ7+ [0] ---- 0.000 0.110 0.546 0.579 4.077
15 - 202245****** IQ7+M [0] ---- 0.000 0.109 0.539 0.569 4.005
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 0.380 1.651 27.281 0.000 kW
0.380 kWh
0.000 kW
0.380 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.81 V Voltage Charge 53.07 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.6 °C / 24.7 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-11-09 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.27 V Current/Power -1.77 A (-94 W)
Remain Capacity/Energy 419.7 Ah (21.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 70.8 % State Of Health 98.9 %
Run Time 9d 21h 8m to empty Report Date 2024-11-09 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.