| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.096 kW | |||
|---|---|---|---|
| 01/31/2026 04:12 (2075 days) | Production | Consumption | NET Usage |
| Now | 0.316 kW | 0.412 kW | 0.096 kW |
| Today | 1.337 kWh (0.317 kW) | 1.838 kWh (0.436 kW) | 0.501 kWh (0.119 kW) |
| - This Week | 22.920 kWh (3.711 kWh/day) | 84.145 kWh (13.625 kWh/day) | 61.225 kWh (9.913 kWh/day) |
| - This Month | 228.818 kWh (7.583 kWh/day) | 568.375 kWh (18.835 kWh/day) | 339.557 kWh (11.253 kWh/day) |
| - This Year | 0.229 MWh (7.583 kWh/day) | 0.568 MWh (18.835 kWh/day) | 0.340 MWh (11.253 kWh/day) |
| Yesterday | 14.995 kWh (0.625 kW) | 14.853 kWh (0.619 kW) | -0.142 kWh (-0.006 kW) |
| Last 7 Days | 35.129 kWh (5.018 kWh/day) | 128.190 kWh (18.313 kWh/day) | 93.061 kWh (13.295 kWh/day) |
| Last 30 Days | 227.481 kWh (7.583 kWh/day) | 566.537 kWh (18.884 kWh/day) | 339.056 kWh (11.302 kWh/day) |
| Last One Year | 6.078 MWh (16.653 kWh/day) | 7.499 MWh (20.546 kWh/day) | 1.421 MWh (3.893 kWh/day) |
| Lifetime Since PTO | 35.795 MWh (17.249 kW/day) | 40.080 MWh (19.314 kW/day) | 4.285 MWh (2.065 kW/day) |
| Lifetime Since Install | 35.828 MWh | 40.660 MWh | 4.831 MWh |
| Voltage/Current | 249.9 V / 1.3 A | 249.9 V / 1.6 A | 249.9 V / 0.4 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 02/03/2025 23:25 (9.3 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 8.300 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.205 | 0.531 | 0.690 | 6.753 | 0.000 kW 0.543 kWh |
0.000 kW 3.256 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.198 | 0.505 | 0.649 | 6.420 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.205 | 0.522 | 0.684 | 6.674 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.205 | 0.541 | 0.685 | 6.676 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.198 | 0.583 | 0.640 | 6.442 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.201 | 0.574 | 0.661 | 6.560 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.265 | 0.703 | 0.651 | 7.041 | 0.000 kW 0.769 kWh |
0.000 kW 3.845 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.265 | 0.723 | 0.680 | 7.744 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.264 | 0.762 | 0.705 | 8.243 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.264 | 0.891 | 0.701 | 8.108 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.265 | 0.766 | 0.685 | 7.887 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.100 | 0.283 | 0.543 | 3.242 | 0.000 kW 0.300 kWh |
0.000 kW 1.199 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.106 | 0.290 | 0.572 | 3.431 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.107 | 0.311 | 0.599 | 3.522 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.107 | 0.315 | 0.598 | 3.608 | |||
| wind | 16 - 202320****** | IQ7XS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 1.17 V | Voltage Charge | 52.14 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 28.1 °C / 24.8 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2025-02-03 23:56 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.39 V | Current/Power | -6.21 A (-0.325 kW) |
| Remain Capacity/Energy | 333.4 Ah (17.1 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 56.2 % | State Of Health | 98.9 % |
| Run Time | 2d 5h 41m to empty | Report Date | 2025-02-03 23:56 |
|
|||