Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.121 kW
05/12/2026 23:18 (2176 days) Production Consumption NET Usage
Now 0.316 kW 0.437 kW 0.121 kW
Today 41.740 kWh (1.791 kW) 11.958 kWh (0.513 kW) -29.782 kWh (-1.278 kW)
  - This Week 81.585 kWh (27.454 kWh/day) 36.719 kWh (12.356 kWh/day) -44.866 kWh (-15.098 kWh/day)
  - This Month 299.660 kWh (25.032 kWh/day) 153.856 kWh (12.852 kWh/day) -145.804 kWh (-12.180 kWh/day)
  - This Year 2.253 MWh (17.070 kWh/day) 2.214 MWh (16.773 kWh/day) -0.039 MWh (-0.296 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 154.358 kWh (22.051 kWh/day) 109.431 kWh (15.633 kWh/day) -44.927 kWh (-6.418 kWh/day)
Last 30 Days (04/12/2026) 708.310 kWh (23.610 kWh/day) 437.919 kWh (14.597 kWh/day) -270.391 kWh (-9.013 kWh/day)
Last One Year 6.298 MWh (17.256 kWh/day) 7.791 MWh (21.346 kWh/day) 1.493 MWh (4.091 kWh/day)
Lifetime Since PTO 37.818 MWh (17.372 kW/day) 41.724 MWh (19.166 kW/day) 3.906 MWh (1.794 kW/day)
Lifetime Since Install 37.852 MWh 42.304 MWh 4.452 MWh
Voltage/Current 251.2 V / 1.3 A 251.2 V / 1.7 A 251.2 V / 0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/30/2025 23:20 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.878 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.292 1.591 0.887 9.008 0.000 kW
1.568 kWh
0.000 kW
9.406 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.542 0.846 8.490
03 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.576 0.876 8.639
04 - 202232****** IQ7+ [0] ---- 0.000 0.292 1.590 0.877 8.744
05 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.539 0.831 7.913
06 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.568 0.872 8.738
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.290 1.534 0.835 8.199 0.000 kW
1.534 kWh
0.000 kW
7.671 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.289 1.526 0.785 7.995
09 - 202217****** IQ7+ [0] ---- 0.000 0.289 1.536 0.822 8.123
10 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.535 0.839 8.244
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.540 0.829 8.236
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.271 1.387 0.759 8.832 0.000 kW
1.450 kWh
0.000 kW
5.801 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.277 1.422 0.787 8.950
14 - 202216****** IQ7+ [0] ---- 0.000 0.279 1.489 0.861 9.434
15 - 202245****** IQ7+M [0] ---- 0.000 0.281 1.502 0.865 9.459
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 1.57 V Voltage Charge 52.53 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.0 °C / 23.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-05-30 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.72 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 269.5 Ah (13.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 45.4 % State Of Health 98.9 %
Run Time 9d 8h 33m to empty Report Date 2025-05-30 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.