Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.112 kW
01/31/2026 03:16 (2075 days) Production Consumption NET Usage
Now 0.318 kW 0.430 kW 0.112 kW
Today 1.042 kWh (0.317 kW) 1.479 kWh (0.450 kW) 0.437 kWh (0.133 kW)
  - This Week 22.625 kWh (3.687 kWh/day) 83.786 kWh (13.652 kWh/day) 61.161 kWh (9.966 kWh/day)
  - This Month 228.523 kWh (7.583 kWh/day) 568.016 kWh (18.848 kWh/day) 339.493 kWh (11.265 kWh/day)
  - This Year 0.229 MWh (7.583 kWh/day) 0.568 MWh (18.848 kWh/day) 0.339 MWh (11.265 kWh/day)
Yesterday 14.995 kWh (0.625 kW) 14.853 kWh (0.619 kW) -0.142 kWh (-0.006 kW)
Last 7 Days 35.129 kWh (5.018 kWh/day) 128.190 kWh (18.313 kWh/day) 93.061 kWh (13.295 kWh/day)
Last 30 Days 227.481 kWh (7.583 kWh/day) 566.537 kWh (18.884 kWh/day) 339.056 kWh (11.302 kWh/day)
Last One Year 6.078 MWh (16.653 kWh/day) 7.499 MWh (20.546 kWh/day) 1.421 MWh (3.893 kWh/day)
Lifetime Since PTO 35.794 MWh (17.249 kW/day) 40.079 MWh (19.314 kW/day) 4.285 MWh (2.065 kW/day)
Lifetime Since Install 35.828 MWh 40.659 MWh 4.831 MWh
Voltage/Current 250.5 V / 1.3 A 250.3 V / 1.7 A 250.4 V / 0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/01/2025 23:56 (12.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.105 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.282 0.868 0.947 5.188 0.000 kW
1.147 kWh
0.000 kW
6.883 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.261 0.620 0.905 5.068
03 - 202224****** IQ7+M [0] ---- 0.000 0.278 0.686 0.926 5.206
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.561 0.943 5.760
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.002 0.913 6.958
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.145 0.913 5.123
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 2.140 0.950 7.893 0.000 kW
1.886 kWh
0.000 kW
9.431 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.111 0.962 6.666
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 2.155 0.955 8.140
10 - 202244****** IQ7+M [0] ---- 0.000 0.283 0.739 0.886 4.997
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 2.285 0.973 8.473
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.236 1.677 0.790 6.721 0.000 kW
1.698 kWh
0.000 kW
6.792 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.241 1.659 0.822 7.347
14 - 202216****** IQ7+ [0] ---- 0.000 0.243 1.737 0.847 7.538
15 - 202245****** IQ7+M [0] ---- 0.000 0.242 1.718 0.843 7.507
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.57 V Voltage Charge 52.29 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.8 °C / 25.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-04-01 23:56
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.