Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.440 kW
06/28/2026 07:40 (2223 days) Production Consumption NET Usage
Now 0.819 kW 0.379 kW -0.440 kW
Today 0.865 kWh (0.113 kW) 2.651 kWh (0.345 kW) 1.786 kWh (0.232 kW)
  - This Week 0.865 kWh (2.702 kWh/day) 2.651 kWh (8.280 kWh/day) 1.786 kWh (5.578 kWh/day)
  - This Month 794.692 kWh (29.087 kWh/day) 645.347 kWh (23.621 kWh/day) -149.345 kWh (-5.466 kWh/day)
  - This Year 3.529 MWh (19.791 kWh/day) 3.215 MWh (18.031 kWh/day) -0.314 MWh (-1.760 kWh/day)
Yesterday 10.018 kWh (0.417 kW) 16.954 kWh (0.706 kW) 6.936 kWh (0.289 kW)
Last 7 Days 134.237 kWh (19.177 kWh/day) 157.658 kWh (22.523 kWh/day) 23.421 kWh (3.346 kWh/day)
Last 30 Days (05/29/2026) 889.623 kWh (29.654 kWh/day) 671.884 kWh (22.396 kWh/day) -217.739 kWh (-7.258 kWh/day)
Last One Year 6.693 MWh (18.336 kWh/day) 7.736 MWh (21.194 kWh/day) 1.043 MWh (2.858 kWh/day)
Lifetime Since PTO 39.095 MWh (17.584 kW/day) 42.726 MWh (19.217 kW/day) 3.631 MWh (1.633 kW/day)
Lifetime Since Install 39.129 MWh 43.306 MWh 4.177 MWh
Voltage/Current 250.4 V / 3.3 A 250.3 V / 1.5 A 250.3 V / -1.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/10/2025 23:45 (23.6 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 19.466 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.210 0.984 1.853 10.691 0.000 kW
0.960 kWh
0.000 kW
5.759 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.937 1.778 10.249
03 - 202224****** IQ7+M [5] VCOP 0.000 0.203 0.976 1.854 10.692
04 - 202232****** IQ7+ [5] VCOP 0.000 0.208 0.976 1.877 10.842
05 - 202244****** IQ7+M [5] VCOP 0.000 0.196 0.929 1.720 9.946
06 - 202245****** IQ7+M [5] VCOP 0.000 0.202 0.957 1.759 10.204
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.201 0.922 1.770 10.330 0.000 kW
0.931 kWh
0.000 kW
4.657 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.205 0.933 1.892 10.798
09 - 202217****** IQ7+ [5] VCOP 0.000 0.207 0.933 1.864 10.662
10 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.930 1.897 10.869
11 - 202224****** IQ7+M [5] VCOP 0.000 0.208 0.940 1.924 11.016
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.171 0.848 1.531 8.888 0.000 kW
0.888 kWh
0.000 kW
3.553 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.179 0.879 1.557 9.048
14 - 202216****** IQ7+ [5] VCOP 0.000 0.178 0.913 1.606 9.337
15 - 202245****** IQ7+M [5] VCOP 0.000 0.179 0.913 1.603 9.355
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.832 kWh
0.230 kW
5.497 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.497 5.500 38.518
Panel Layout Each Group Production

Charger History
Voltage PV 0.98 V Voltage Charge 52.28 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.1 °C / 27.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-10 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.55 V Current/Power -6.28 A (-0.330 kW)
Remain Capacity/Energy 324.9 Ah (16.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 54.8 % State Of Health 98.9 %
Run Time 2d 3h 44m to empty Report Date 2025-09-10 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.