Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.386 kW
05/12/2026 23:26 (2176 days) Production Consumption NET Usage
Now 0.317 kW 0.703 kW 0.386 kW
Today 41.783 kWh (1.782 kW) 12.013 kWh (0.512 kW) -29.770 kWh (-1.270 kW)
  - This Week 81.628 kWh (27.417 kWh/day) 36.774 kWh (12.351 kWh/day) -44.854 kWh (-15.065 kWh/day)
  - This Month 299.703 kWh (25.023 kWh/day) 153.911 kWh (12.851 kWh/day) -145.792 kWh (-12.173 kWh/day)
  - This Year 2.253 MWh (17.069 kWh/day) 2.214 MWh (16.773 kWh/day) -0.039 MWh (-0.296 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 154.401 kWh (22.057 kWh/day) 109.671 kWh (15.667 kWh/day) -44.730 kWh (-6.390 kWh/day)
Last 30 Days (04/12/2026) 708.317 kWh (23.611 kWh/day) 437.896 kWh (14.597 kWh/day) -270.421 kWh (-9.014 kWh/day)
Last One Year 6.298 MWh (17.256 kWh/day) 7.791 MWh (21.346 kWh/day) 1.493 MWh (4.090 kWh/day)
Lifetime Since PTO 37.818 MWh (17.372 kW/day) 41.724 MWh (19.166 kW/day) 3.906 MWh (1.794 kW/day)
Lifetime Since Install 37.852 MWh 42.304 MWh 4.452 MWh
Voltage/Current 251.5 V / 1.3 A 251.4 V / 2.8 A 251.4 V / 1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 08/04/2025 23:58 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 33.860 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.273 2.018 2.149 11.682 0.000 kW
1.931 kWh
0.000 kW
11.584 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.259 1.888 2.000 10.951
03 - 202224****** IQ7+M [0] ---- 0.000 0.268 1.958 2.074 11.300
04 - 202232****** IQ7+ [0] ---- 0.000 0.273 1.994 2.130 11.550
05 - 202244****** IQ7+M [0] ---- 0.000 0.260 1.788 1.873 10.247
06 - 202245****** IQ7+M [0] ---- 0.000 0.265 1.939 2.051 11.262
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.267 1.867 1.994 10.685 0.000 kW
1.877 kWh
0.000 kW
9.385 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.271 1.860 1.972 10.504
09 - 202217****** IQ7+ [0] ---- 0.000 0.268 1.862 1.973 10.574
10 - 202244****** IQ7+M [0] ---- 0.000 0.266 1.881 2.007 10.727
11 - 202224****** IQ7+M [0] ---- 0.000 0.273 1.916 2.052 10.872
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.226 1.806 1.974 11.028 0.000 kW
1.847 kWh
0.000 kW
7.389 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.230 1.827 1.964 11.111
14 - 202216****** IQ7+ [0] ---- 0.000 0.231 1.874 2.044 11.548
15 - 202245****** IQ7+M [0] ---- 0.000 0.233 1.881 2.052 11.605
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.751 kWh
0.230 kW
5.502 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.231 5.502 5.507 14.347
Panel Layout Each Group Production

Charger History
Voltage PV 0.89 V Voltage Charge 52.48 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 32.0 °C / 29.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-04 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.75 V Current/Power -6.43 A (-0.339 kW)
Remain Capacity/Energy 382.7 Ah (19.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 64.5 % State Of Health 98.9 %
Run Time 2d 11h 30m to empty Report Date 2025-08-04 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.