Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.851 kW
06/28/2026 09:12 (2223 days) Production Consumption NET Usage
Now 2.060 kW 0.209 kW -1.851 kW
Today 2.381 kWh (0.258 kW) 3.349 kWh (0.363 kW) 0.968 kWh (0.105 kW)
  - This Week 2.381 kWh (6.201 kWh/day) 3.349 kWh (8.722 kWh/day) 0.968 kWh (2.521 kWh/day)
  - This Month 796.208 kWh (29.074 kWh/day) 646.045 kWh (23.591 kWh/day) -150.163 kWh (-5.483 kWh/day)
  - This Year 3.531 MWh (19.792 kWh/day) 3.216 MWh (18.028 kWh/day) -0.315 MWh (-1.764 kWh/day)
Yesterday 10.018 kWh (0.417 kW) 16.954 kWh (0.706 kW) 6.936 kWh (0.289 kW)
Last 7 Days 134.216 kWh (19.174 kWh/day) 158.207 kWh (22.601 kWh/day) 23.991 kWh (3.427 kWh/day)
Last 30 Days (05/29/2026) 889.506 kWh (29.650 kWh/day) 671.705 kWh (22.390 kWh/day) -217.801 kWh (-7.260 kWh/day)
Last One Year 6.694 MWh (18.339 kWh/day) 7.736 MWh (21.194 kWh/day) 1.042 MWh (2.856 kWh/day)
Lifetime Since PTO 39.096 MWh (17.584 kW/day) 42.727 MWh (19.217 kW/day) 3.630 MWh (1.633 kW/day)
Lifetime Since Install 39.130 MWh 43.307 MWh 4.177 MWh
Voltage/Current 250.3 V / 8.2 A 250.4 V / 0.8 A 250.4 V / -7.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/22/2025 23:54 (23.7 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 20.252 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.242 1.040 1.541 10.320 0.000 kW
1.015 kWh
0.000 kW
6.091 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.231 0.990 1.483 9.879
03 - 202224****** IQ7+M [5] VCOP 0.000 0.240 1.029 1.539 10.241
04 - 202232****** IQ7+ [5] VCOP 0.000 0.245 1.039 1.552 10.319
05 - 202244****** IQ7+M [5] VCOP 0.000 0.233 0.982 1.449 9.593
06 - 202245****** IQ7+M [5] VCOP 0.000 0.239 1.013 1.484 9.824
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.270 1.048 1.549 9.765 0.000 kW
1.064 kWh
0.000 kW
5.319 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.061 1.630 10.561
09 - 202217****** IQ7+ [5] VCOP 0.000 0.274 1.064 1.628 10.536
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 1.068 1.634 10.540
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.078 1.645 10.689
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.148 0.794 1.139 8.011 0.000 kW
0.835 kWh
0.000 kW
3.339 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.152 0.826 1.165 8.169
14 - 202216****** IQ7+ [5] VCOP 0.000 0.154 0.857 1.211 8.458
15 - 202245****** IQ7+M [5] VCOP 0.000 0.157 0.863 1.212 8.460
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.834 kWh
0.230 kW
5.502 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.502 5.498 38.537
Panel Layout Each Group Production

Charger History
Voltage PV 0.51 V Voltage Charge 52.17 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.1 °C / 27.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-22 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.44 V Current/Power -6.32 A (-0.331 kW)
Remain Capacity/Energy 196.4 Ah (10.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 33.1 % State Of Health 98.9 %
Run Time 1d 7h 4m to empty Report Date 2025-09-22 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.