Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.140 kW
05/12/2026 23:45 (2176 days) Production Consumption NET Usage
Now 0.316 kW 0.456 kW 0.140 kW
Today 41.883 kWh (1.763 kW) 12.122 kWh (0.510 kW) -29.761 kWh (-1.253 kW)
  - This Week 81.728 kWh (27.330 kWh/day) 36.883 kWh (12.334 kWh/day) -44.845 kWh (-14.996 kWh/day)
  - This Month 299.803 kWh (25.004 kWh/day) 154.020 kWh (12.846 kWh/day) -145.783 kWh (-12.159 kWh/day)
  - This Year 2.253 MWh (17.068 kWh/day) 2.214 MWh (16.772 kWh/day) -0.039 MWh (-0.296 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 154.501 kWh (22.072 kWh/day) 110.199 kWh (15.743 kWh/day) -44.302 kWh (-6.329 kWh/day)
Last 30 Days (04/12/2026) 708.309 kWh (23.610 kWh/day) 437.791 kWh (14.593 kWh/day) -270.518 kWh (-9.017 kWh/day)
Last One Year 6.299 MWh (17.256 kWh/day) 7.791 MWh (21.346 kWh/day) 1.493 MWh (4.090 kWh/day)
Lifetime Since PTO 37.819 MWh (17.372 kW/day) 41.725 MWh (19.166 kW/day) 3.906 MWh (1.794 kW/day)
Lifetime Since Install 37.852 MWh 42.304 MWh 4.452 MWh
Voltage/Current 251.7 V / 1.3 A 251.7 V / 1.8 A 251.7 V / 0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 08/27/2025 23:56 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 29.460 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.674 1.703 10.664 0.000 kW
1.621 kWh
0.000 kW
9.728 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.601 1.616 10.138
03 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.665 1.684 10.555
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.696 1.724 10.775
05 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.508 1.525 9.724
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.583 1.599 10.175
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.540 1.559 10.131 0.000 kW
1.562 kWh
0.000 kW
7.811 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.535 1.582 10.255
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.524 1.570 10.183
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.593 1.616 10.372
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.620 1.641 10.571
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.263 1.570 1.585 9.248 0.000 kW
1.604 kWh
0.000 kW
6.417 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.260 1.599 1.602 9.352
14 - 202216****** IQ7+ [0] ---- 0.000 0.261 1.624 1.642 9.659
15 - 202245****** IQ7+M [0] ---- 0.000 0.262 1.624 1.643 9.675
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.752 kWh
0.230 kW
5.504 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.504 5.485 38.433
Panel Layout Each Group Production

Charger History
Voltage PV 0.33 V Voltage Charge 52.85 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.1 °C / 28.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-27 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.13 V Current/Power -6.16 A (-0.327 kW)
Remain Capacity/Energy 493.7 Ah (25.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 83.2 % State Of Health 98.9 %
Run Time 3d 8h 8m to empty Report Date 2025-08-27 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.