Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.275 kW
01/31/2026 00:57 (2075 days) Production Consumption NET Usage
Now 0.316 kW 0.591 kW 0.275 kW
Today 0.307 kWh (0.316 kW) 0.366 kWh (0.377 kW) 0.059 kWh (0.061 kW)
  - This Week 21.890 kWh (3.624 kWh/day) 82.673 kWh (13.686 kWh/day) 60.783 kWh (10.062 kWh/day)
  - This Month 227.788 kWh (7.583 kWh/day) 566.903 kWh (18.871 kWh/day) 339.115 kWh (11.289 kWh/day)
  - This Year 0.228 MWh (7.583 kWh/day) 0.567 MWh (18.871 kWh/day) 0.339 MWh (11.289 kWh/day)
Yesterday 14.995 kWh (0.625 kW) 14.853 kWh (0.619 kW) -0.142 kWh (-0.006 kW)
Last 7 Days 35.129 kWh (5.018 kWh/day) 128.190 kWh (18.313 kWh/day) 93.061 kWh (13.295 kWh/day)
Last 30 Days 227.481 kWh (7.583 kWh/day) 566.537 kWh (18.884 kWh/day) 339.056 kWh (11.302 kWh/day)
Last One Year 6.078 MWh (16.653 kWh/day) 7.499 MWh (20.546 kWh/day) 1.421 MWh (3.893 kWh/day)
Lifetime Since PTO 35.793 MWh (17.249 kW/day) 40.078 MWh (19.314 kW/day) 4.285 MWh (2.065 kW/day)
Lifetime Since Install 35.827 MWh 40.658 MWh 4.831 MWh
Voltage/Current 250.1 V / 1.3 A 250.1 V / 2.4 A 250.1 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/24/2025 23:45 (14.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.220 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.281 2.252 2.119 10.259 0.000 kW
2.107 kWh
0.000 kW
12.644 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.265 2.088 1.970 9.647
03 - 202224****** IQ7+M [0] ---- 0.000 0.272 2.104 1.994 9.749
04 - 202232****** IQ7+ [0] ---- 0.000 0.275 2.143 2.033 9.890
05 - 202244****** IQ7+M [0] ---- 0.000 0.265 1.884 1.786 8.807
06 - 202245****** IQ7+M [0] ---- 0.000 0.271 2.172 2.041 9.951
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.266 1.995 1.895 9.298 0.000 kW
1.974 kWh
0.000 kW
9.871 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.268 1.903 1.869 9.074
09 - 202217****** IQ7+ [0] ---- 0.000 0.266 1.946 1.884 9.237
10 - 202244****** IQ7+M [0] ---- 0.000 0.263 1.995 1.890 9.311
11 - 202224****** IQ7+M [0] ---- 0.000 0.270 2.033 1.913 9.316
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.243 2.149 1.997 9.849 0.000 kW
2.176 kWh
0.000 kW
8.706 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.247 2.128 2.007 9.947
14 - 202216****** IQ7+ [0] ---- 0.000 0.246 2.212 2.075 10.410
15 - 202245****** IQ7+M [0] ---- 0.000 0.247 2.216 2.085 10.462
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.39 V Voltage Charge 53.27 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.8 °C / 27.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-06-24 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.48 V Current/Power -2.16 A (-0.116 kW)
Remain Capacity/Energy 532.5 Ah (27.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 89.8 % State Of Health 98.9 %
Run Time 10d 6h 31m to empty Report Date 2025-06-24 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.