Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.258 kW
07/17/2026 15:34 (2242 days) Production Consumption NET Usage
Now 3.777 kW 2.519 kW -1.258 kW
Today 26.684 kWh (1.713 kW) 14.035 kWh (0.901 kW) -12.649 kWh (-0.812 kW)
  - This Week 172.711 kWh (30.575 kWh/day) 182.976 kWh (32.393 kWh/day) 10.265 kWh (1.817 kWh/day)
  - This Month 443.265 kWh (26.623 kWh/day) 580.939 kWh (34.892 kWh/day) 137.674 kWh (8.269 kWh/day)
  - This Year 4.053 MWh (20.507 kWh/day) 3.868 MWh (19.569 kWh/day) -0.185 MWh (-0.938 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 205.827 kWh (29.404 kWh/day) 232.095 kWh (33.156 kWh/day) 26.268 kWh (3.753 kWh/day)
Last 30 Days (06/17/2026) 747.300 kWh (24.910 kWh/day) 872.699 kWh (29.090 kWh/day) 125.399 kWh (4.180 kWh/day)
Last One Year 6.738 MWh (18.462 kWh/day) 7.646 MWh (20.949 kWh/day) 0.908 MWh (2.488 kWh/day)
Lifetime Since PTO 39.619 MWh (17.666 kW/day) 43.378 MWh (19.343 kW/day) 3.760 MWh (1.676 kW/day)
Lifetime Since Install 39.653 MWh 43.958 MWh 4.306 MWh
Voltage/Current 248.1 V / 15.2 A 248.1 V / 10.2 A 248.1 V / -5.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/31/2020 23:38 (12.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.251 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.262 1.065 1.837 11.144 0.000 kW
1.047 kWh
0.000 kW
6.283 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.054 1.820 10.966
03 - 202224****** IQ7+M [5] VCOP 0.000 0.263 1.074 1.854 11.178
04 - 202232****** IQ7+ [5] VCOP 0.000 0.261 1.062 1.866 11.207
05 - 202244****** IQ7+M [5] VCOP 0.000 0.259 1.002 1.815 10.622
06 - 202245****** IQ7+M [5] VCOP 0.000 0.258 1.026 1.813 10.769
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.267 1.002 1.820 10.814 0.000 kW
1.004 kWh
0.000 kW
5.022 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.271 0.977 1.891 10.785
09 - 202217****** IQ7+ [5] VCOP 0.000 0.268 1.008 1.796 10.790
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 1.022 1.887 11.038
11 - 202224****** IQ7+M [5] VCOP 0.000 0.270 1.012 1.910 11.029
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.205 0.982 1.595 9.945 0.000 kW
0.987 kWh
0.000 kW
3.947 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.211 0.981 1.525 9.694
14 - 202216****** IQ7+ [5] VCOP 0.000 0.210 0.998 1.595 9.950
15 - 202245****** IQ7+M [5] VCOP 0.000 0.205 0.986 1.568 9.784
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.