Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.298 kW
05/31/2026 00:52 (2195 days) Production Consumption NET Usage
Now 0.000 kW 0.298 kW 0.298 kW
Today 0.000 kWh (0.000 kW) 0.366 kWh (0.414 kW) 0.366 kWh (0.414 kW)
  - This Week 0.000 kWh 0.366 kWh 0.366 kWh
  - This Month 750.533 kWh (24.988 kWh/day) 503.720 kWh (16.770 kWh/day) -246.813 kWh (-8.217 kWh/day)
  - This Year 2.704 MWh (18.019 kWh/day) 2.563 MWh (17.085 kWh/day) -0.140 MWh (-0.934 kWh/day)
Yesterday 29.923 kWh (1.247 kW) 6.471 kWh (0.270 kW) -23.452 kWh (-0.977 kW)
Last 7 Days 188.538 kWh (26.934 kWh/day) 147.598 kWh (21.085 kWh/day) -40.940 kWh (-5.849 kWh/day)
Last 30 Days (05/01/2026) 750.533 kWh (25.018 kWh/day) 503.665 kWh (16.789 kWh/day) -246.868 kWh (-8.229 kWh/day)
Last One Year 6.434 MWh (17.627 kWh/day) 7.796 MWh (21.358 kWh/day) 1.362 MWh (3.731 kWh/day)
Lifetime Since PTO 38.269 MWh (17.434 kW/day) 42.074 MWh (19.168 kW/day) 3.805 MWh (1.733 kW/day)
Lifetime Since Install 38.303 MWh 42.654 MWh 4.351 MWh
Voltage/Current 250.6 V / 0.0 A 250.7 V / 1.2 A 250.6 V / 1.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/15/2020 23:10 (12.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.350 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.254 1.632 1.465 9.138 0.000 kW
1.617 kWh
0.000 kW
9.704 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.253 1.614 1.448 9.061
03 - 202224****** IQ7+M [0] ---- 0.000 0.255 1.637 1.468 9.236
04 - 202232****** IQ7+ [0] ---- 0.000 0.252 1.627 1.453 9.169
05 - 202244****** IQ7+M [0] ---- 0.000 0.252 1.594 1.438 8.870
06 - 202245****** IQ7+M [0] ---- 0.000 0.251 1.600 1.443 8.896
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.269 1.686 1.475 9.219 0.000 kW
1.683 kWh
0.000 kW
8.416 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.269 1.641 1.430 9.005
09 - 202217****** IQ7+ [0] ---- 0.000 0.266 1.695 1.485 9.183
10 - 202244****** IQ7+M [0] ---- 0.000 0.267 1.704 1.496 9.427
11 - 202224****** IQ7+M [0] ---- 0.000 0.266 1.690 1.485 9.356
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.198 1.313 1.212 7.794 0.000 kW
1.308 kWh
0.000 kW
5.230 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.199 1.297 1.203 7.679
14 - 202216****** IQ7+ [0] ---- 0.000 0.199 1.320 1.217 7.868
15 - 202245****** IQ7+M [0] ---- 0.000 0.197 1.300 1.195 7.749
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 180.03 A (10.373 kW)
Remain Capacity/Energy 579.3 Ah (29.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.0 % State Of Health 98.5 %
Run Time 3m to full Report Date 2020-09-15 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.